TM 5-6115-634-14&PNAVFAC P-8-647-14&PTO-35C2-3-445-14(i) Connect a damp (9) to top of the groundrod and reconnect the ground rod coupler (5). Connectloose end of the ground wire assembly to the damp.Tighten the damp screw (10). Ensure that all groundwire connections are tight.b. CableConnectionsforasinglePU794/GWhen making cable connections, PU794/6 must be shut down. Failure toobserve this warning could result indeath by electrocution.(1) Remove all the cables from the reel andtray.(2) Connect the 5-foot (1.52 meters) controlcable between the control connector on the connectorplate and the control connection on the junction box forunit 1 (Figure 2-3).(3) Connect the 100-foot (30.46 meters) con-trol cable to the remote connector on the junction box.Connect the other end of the control cable to the con-trol cable connection on the front of the shelter (Fig-ures 2-3 and 2-4).(4) Connect one end of the power cable to thepower connector on the generator (not on the junctionbox), and the other end of the power cable to the con-nector on the shelter.All pins are live on the junction boxpower connectors.Power connections on the junctionbox should not be used for single unitoperation.All connectors are hot when used. Donot remove caps from unused hocks.2-12Change 6(5) Deleted.c. CableConnectionsfortwoPU794/Gs.NOTETwo PU 794’s are not to be continu-ously operated in parallel, only totransfer power.When making cable connections,both PU 794/Gs must be shut downdue to feedback from and operatingunit. Failure to observe this warningcould result in death by electrocution.(1) Connect the first PU 794/G following para-graph b. above. Designate this unit as unit number 1.All connections to the junction box will be made at thisunit.(2) Connect the grounding wire of the secondPU 794/G to the ground rod of the first PU 794/G.(3) Connect the 25-foot (7.62 meters) controlcable from the control connector on the connectorplate of unit 2 to the unit 2 control connection of thejunction box on unit 1 (Figure 2-5).(4) Connect the 25-foot (7.62 meters) powercable between the power connector on the connectorplate of unit 2 and the unit 2 power connection of thejunction box on unit 1 (Figure 2-5)(5) Connect the 25-foot (7.62 meters) parallelcable to the parallel connectors on both unit 1 and unit2 (Figures 2-3 and 2-5).(6) At both generator sets place the PARALLELOPERATION/SINGLE UNIT OPERATION switch onthe generator control panel to the PARALLEL OPERA-TION position.2-4. Initial AdjustmentsPerform the PMCS in Table 2-1 before operating thePU 794/G.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business