Ground Wire Replacement (5-Wire Switch Box)
Male Connector Replacement

Power Plant An/Mjq-18 (Nsn 6115-00-033-1398) (2) Mep-003A 10Kw 60Hz Generator Sets M103A3 2-Wheel, 1-1/2 Ton Modified Trailer Page Navigation
  51    52    53    54    55  56  57    58    59    60    61  
img
ARMY TM 5-6115-633-14&P
Figure 4-14. Ground Wire Replacement.
(b) Remove nut (6) and flat washer (7) from load terminal L0 (8) inside switch box (5).
(c) Slide power cable ground (white) wire terminals (9) and switch box ground wire terminal
(10) off load terminal L0 (8).
(d) Remove nut (11) and flat washer (12) from AC GROUND terminal E2 (13) inside switch
box (5). Side ground wire terminal (14) off terminal E2.
(2) Installation.
(a) Install switch box ground wire terminal (14) on AC GROUND terminal E2 (13) and secure
with flat washer (12) and nut (11).
(b) Install other switch box ground wire terminal (10) on load terminal L0 (8). Install power
cable ground (white) wire terminals (9) on terminal L0 and secure both wires with flat
washer (7) and nut (6).
(c) Position cover (4) on switch box (5) and secure with 16 screws (1), 16 Iockwashers (2)
and 16 flat washers (3).