TM 5-6115-593-12TO 35C2-3-463-1(2) Inspect connections for security andcondition.(3) Inspect wiring for defective insulation.b. Test. Perform continuity check, usingohmmeter between connecting points in thewiring harness. (See FO-7, Control Cubicle,Wiring Diagram.) Check for short circuitsbetween connector pins of the samereceptacle or terminal board.c. Repair.(1) If a broken wire is accessible, removesufficient insulation from each side ofthe break to allow a good connectionof the bared ends by twisting themtogether. Solder the connection andwrap with electrical tape.(2) If a wire is broken from a terminallug, replace the lug. If a wire isbroken from a connector, resolder andreassemble.CAUTIONUnder no condition leave the bareconnection exposed.(3) If a break in the wire is inaccessiblewithin the wiring harness, disconnectit at both ends and tape both ends.Lace a new lead of the same gaugeand insulation outside the harnessand connect it to the proper terminalsor pins. Properly tag both ends of allreplacement wires.d. Replacement. If 30 percent of the harnesswires are defective, refer to next higherlevel of maintenance for replacement.Section XIII. MAINTENANCE OF AIR CLEANER4-42. AIR CLEANER. (See figure 4-23.)a. Removal. Remove both air cleaners asfollows:(1) Loosen eight hose clamps (24).(2) Remove six screws (15), nuts (16),and lockwashers (17) from mountingbrackets (18 and 19).(3) Remove air cleaners (29).b. Service. Check the air cleaner serviceindicator. If indicator is in red, proceed asfollows (see figure 3-1):(1) Remove and empty dust cup (13)when three-quarters full.(2) Reinstall dust cup (13) and O-ring(14).(3) Clean air cleaner tubes with a stiffbrush. If heavy plugging is evident,remove lower body section (15) andclean with compressed air or waternot exceeding 1600F (71°C).CAUTIONNever clean air cleaner tubes withcompressed air unless both filterelements are installed in the air cleaner.Do not steam clean air cleaner tubes.(4) Unfasten cover latches and removecover (1). Remove wing nut (3) andremove primary filter element (4).(5) Remove cotter pin (5), castellated nut(6), and safety filter element(7).Replace with new element atinterval indicated in table 4-2 andsecure with castellated nut (6) andcotter pin (5). Do not clean safetyfilter element (7).(6) Clean primary filter element (4) byeither method (a) or (b), as follows:4-71
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business