TM5-6115-585-34NAVFAC P-8-262-12TO-35C2-3-455-2TM-05684C-34Table 2-3. Troubleshooting (Cont)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION15. STICKING VALVES (CONT).Step 3. Check clearance between valve stem and guide (paragraph 7-9).Correct clearance.16. ENGINE RUNS NORMALLY BUT GENERATOR HAS NO OUTPUT.Step 1.Step 2.Step 3.Step 4.Step 5.Step 6.Step 7.Step 8.Check voltage regulator (paragraph 6-6).Repair or replace regulator.Check exciter field (stator) for open or shorted windings (paragraph 8-2).Replace stator if necessary.Check diodes on exciter rotor (paragraph 8-2).Replace diodes if necessary.Check generator field (rotor) for open or shorted windingsReplace rotor if necessary.Check generator rotor flashing circuit (paragraph 6-9).Replace diode CR2 or bridge rectifier.(paragraph 8-2).Check generator stator for open, shorted, or grounded windings (paragraph 8-2).Replace stator if necessary.Check exciter rotor for open, shorted, or grounded windings (paragraph 8-2).Replace exciter rotor if necessary.Check bridge assembly A4 for defective resistor or diodes (paragraph 6-9).Replace defective resister or diodes17. ENGINE RUNS NORMALLY BUT GENERATOR HAS LOW OUTPUT.Step 1. Check voltage regulator (paragraph 6-6).Adjust, repair, or replace regulator.Step 2. Check generator stator for open or shorted windings (paragraph 8-2).Replace stator.Step 3. Check exciter rotor for shorted windings (paragraph 8-2).Replace rotor.Step 4. Check diodes on exciter rotor (paragraph 8-2).Replace diodes as necessary.2-10
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business