TM 5-6115-585-34
NAVFAC P-8-623-34
TO-35C2-3-455-2
TM-05684C/05685B-34
Table 2-2. Fabricated Tools and Equipment (Cont)
Nomenclature
Reference No. or NSN
Material Required
Camshaft/crankshaft
Steel, round, CD
gear puller ring
Fabrication Instructions:
Make puller according to dimensions shown below.
Sketch or Diagram:
Section II.
TROUBLESHOOTING
2-4. GENERAL.
2-5. MALFUNCTIONS NOT CORRECTED BY
USE OF THE TROUBLESHOOTING
This section contains troubleshooting information for
TABLE.
locating and correcting operating troubles which may
develop in the Generator Set. Each malfunction for an
This manual cannot list all malfunctions that may oc-
individual component unit, or system is followed by
cur, nor all tests or inspections and corrective actions.
a list of tests or inspections which will help you to
If a malfunction is not listed or cannot be corrected
determine probable causes and corrective actions to
by listed corrective actions, notify your supervisor.
take. You should perform the tests/inspections and
corrective actions in the order listed.
Change 5 2 -5