T M 5 - 6 1 1 5 - 5 8 5 - 12
N A V F A C P - 8 - 6 2 3 - 12
T O - 3 5 C 2 - 3 - 4 5 5 -1
T M - 0 5 6 8 4 C / 0 5 6 8 5 B - 12
F i g u r e 3 - 7 . E l e c t r i c S t a r t er
3-17. AC OUTPUT CONTROL BOX ASSEMBLY.
a. Inspect (see figure 3-8).
( 1 ) C o n t r o l B o x A s s e m b l y . C h e c k b o x a s s e m b l y
f o r c r a c k s , d e n t s , o r o t h e r p h y s i c a l d a m a g e . I n s p e ct
t o s e e t h a t c o v e r s ( 1 ) f o r b o t h 1 2 0 v o l t a c o u t l e t s
o p e r a t e p r o p e r l y ( M E P - 0 0 3 A o n l y ) . C h e c k l a t c h e s ( 2)
s e c u r i n g l o a d t e r m i n a l b o a r d c o v e r ( 3 ) . C h e c k t o s e e
t h a t c o v e r ( 3 ) f o r l o a d t e r m i n a l b o a r d o p e n s a nd
c l o s e s p r o p e r l y . C h e c k t o s e e t h a t e l e c t r i c a l c o n n e c -
tors (4) are clean and securely mounted.
( 2 ) L o a d T e r m i n a l B o a r d A s s e m b l y . C h e c k c o n-
d i t i o n o f l o a d t e r m i n a l b o a r d ( 5 ) a n d l o a d t e r m i n a ls
( 6 ) f o r c l e a n l i n e s s a n d t i g h t n e s s . M a k e c e r t a i n t h at
the load leads are secured to terminals.
3 - 1 8 . A I R C L E A N E R A S S E M B L Y.
a. Inspect on Equipment (see figure 3-9). On ASK equipped
generators, open AIR INTAKE and AIR CLEANER access doors.
(1) Housing. Inspect housing (8) for dirt, grease,
d e n t s o r o t h e r p h y s i c a l d a m a g e . C h e c k t o s e e t h a t
housing is securely attached to bracket assembly (1).
Figure 3-8. AC Output Control Box Assembly
Check that clamp (17) attaching dust cap (18) to hous-
ing is secure and arrows on dust cap are pointing up.
C h e c k t h a t t w o c l a m p s ( 7 ) h o l d i n g c o l d w e a t h er
operation intake hose (19) are secure.
( 2 ) B r a c k e t A s s e m b l y . I n s p e c t b r a c k e t a s s e m b l y
( 1 ) t o s e e t h a t i t i s s e c u r e l y f a s t e n e d t o g e n e r a t or
housing (2). Check that capscrews (3) and lockwashers
( 4 ) w h i c h a t t a c h b r a c k e t t o g e n e r a t o r h o u s i n g , a n d
three spacers (5) are in place.
( 3 ) I n l e t S h u t t e r ( s e e f i g u r e 3 - 1 0 ) . C h e c k i n l et
s h u t t e r ( 6 ) t o s e e t h a t i t s l i d e s e a s i l y f r o m C O L D
WEATHER to NORMAL WEATHER position and back.
( 4 ) A i r F l o w I n d i c a t o r ( s e e f i g u r e 3 - 1 0 ) . C h e c k
a i r f l o w i n d i c a t o r ( 7 ) f o r d i r t , g r e a s e , p h y s i c a l d a m -
age, or if the red flag is visible.
3 - 14
C h a n g e 8