Figure 1-6.
b. Tabulated Data. (Cont)
(4) Main generator (400 Hz,
DOD drawing no. . . . . . 70-1901
tactical precise).
Type . . . . . . . . . . . . . Rotating field synchronous,
brushless with integral
exciter
KVA (Kilovolt Amperes) . . . 75
KW . . . . . . . . . . . . . . . ..60
Hertz . . . . . . . . . . . . . . . . 400
Volts . . . . . . . . . . . . . l20/208 or 240/416
(Adjustable to 197/229 or
395 458 - fig, 1-10)
Amperes . . . . . . . . . . 208/104
Phases . . . . . . . . . . . . 3
Change 3
Power factor . . . . . . . . 0.8
Coating . . . . . . . . . .. Air
Degree of enclosure . . . . . . Drip-proof
Lubrication . . . . . . . . . . . . None required
Drive . . . . . . . . . . . . . . . . Direct
Duty classification . . . . . . . Continuous
Operating speed . . . . . . . . .2000 rpm
(5) Fuel level switch (day tank).
DOD drawing no. . . . . . 70-1594
Type . . . . . . . . . . . . . Float
Current . . . . . . . . . .
3.0 amperes at
6 to 32 Vdc
Pressure . . . . . . . . . . 0 to 150 psi
1 - 8