Figure 1-9. Operational Data Information Plate (Mode I)
b. Tabulated Data. (Cent)
(e) Oil cooler.
Type . . . . . . . . . Permanent tubular element
(f) Radiator.
DOD drawing no . . . 70-1126
Capacity .
Pressure.
(g)
Type . . .
(h)
1.
. . . . . . 15 quarts
. . . . . . 7 psi
Water Pump.
. . . . . . Belt driven
Safety devices:
Low oil pressure switch.
DOD part no. . . . . 70-1309
Contact Rating
A . . . 10 amperes 28 volt dc resistive
B . . . 10 amperes 125 volt ac resistive
Switch Configuration
A . . .
1 circuit N. O.
B . . .
1 circuit N. C.
Pressure Range:
500 psi maximum
Pressure Setting
A . . .
A-D circuit trip at 18-22 psi decreasing
(N. O.)
B . . .
B-C circuit trip at 18-22 psi decreasing
(N. C.)
2. Coolant high temperature switch.
DOD drawing no. . . 69-697-3
Rating
volts . . . . . . . . . . .
Current . . . . . . . . .
Trip temperature . . . .
3. Overspeed switch.
DOD drawing no . . . . .
28 dc
10 amperes
222° F ± 3° F
70-1105-1 (400 Hz)
70-1105-2 (50/60 Hz)
Change 1