• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
2-4 INITIAL ADJUSTMENTS, CHECKS, AND SELF TEST. - TM-9-6115-660-13P_69
2-5.3.3 Stopping  Generator Set.

TM-9-6115-660-13P Power Plant Diesel Engine Driven 1-Ton Trailer Mounted (With Racks) 3Kw 60 Hz AN/MJQ-42 Manual
Page Navigation
  40    41    42    43    44  45  46    47    48    49    50  
TM  9-6115-660-13&P d. e. f. g. h. i. Refer to TM 9-6115-642-10 and: (1)  Start  one  of  the  generator  sets. (2)  Use  generator  set  VOLTAGE  adjustable  rheostat  to  adjust  voltage  to  required  value. (3) Using  generator  set  frequency  adjust  control,  adjust  frequency  to  required  value. (4)  Set  AC  CIRCUIT  INTERRUPTER  switch  on  the  operating  generator  set  to  CLOSED position. Check switch box to make sure  that GEN SET ON light (8 or 2) is lit for generator set just started. Set switch box ON/OFF switch (6 or 4) below lit GEN SET ON light to ON position. Check that switch box ON light (8 or 2)  and ON LINE light (7 or 3) for operating generator set are both lit. The generator set is now supplying power to the connected load. Observe frequency meter and readjust to proper frequency for load if required. Refer to table 2-2 and perform generator set “During” PMCS. 2-5.3.2 Load Transfer. a.  For  the  generator  set  that  is  not  operating: (1) (2) (3) (4) (5) (6) 2-36 Refer to table 2-2 and perform the “Before” PMCS. Check that switch box ON/OFF switch (6 or 4) is at center position. Check that switch box TRANSFER switch (5) is at bottom position. Refer to TM 9-6115-642-10 and: (a) Start the generator set. (b) Use generator set VOLTAGE  adjustable rheostat to adjust voltage to required value. (c)  Using  generator  set  frequency  adjust  control,  adjust  frequency  to  required  value. (d)  Set  AC  CIRCUIT  INTERRUPTER  switch  to  CLOSED  position. Check switch box controls and indicators (figure 2-9) to ensure that: (a) GEN SET ON light (8 or 2) and ON LINE light (7 or 3) is lit for generator set that has been supplying electric power to the load. (b) GEN SET ON light (8 or 2) for generator set just started is lit. Move switch box TRANSFER switch (5) in the direction of the arrow. All SYNCHRONIZING lights (1 and 9) should be going from bright to dark at the same time. If SYNCHRONIZING lights do not begin to function, report problem to next higher level of maintenance.







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.