TM 9-6115-668-135.55 Cooling Blower Assembly Maintenance.This task covers:a. Removalb. Servicec. InstallationINITIALSETUPToolsEquipmentConditionsGeneral Mechanic's Tool KitReference(item 2, appendix B) Generator Set, 150kw, shut down,Puller for Centrifugal Oilparagraph 2.5.2Filter (PN 160010)Sling/hoisting device, Universal(item 7 appendix B)WARNINGDisconnect the negative battery cable first and then the positive battery terminalcable. Failure to observe this warning could result in severe personal injury ordeath.REMOVAL1.Remove unit hood assembly IAW Paragraph 4.14.2.Remove oil line (27) from cover (7).3.Remove screw cap hexagon (4), washer spring tension (5), washer flat (6), and remove cover (7).4.Remove screw cap hexagon (4), washer spring tension (5) and ring (9).5.Remove cover filter ( I 0) with puller (PN 160010).SERVICE1.Clean cover filter (10) and coupling clutch (15) with solvent and cloth to remove old oil and build up.2.Replace O-ring (8) and O-ring (I 1).INSTALLATION1.Install cover filter (10), ring (9), washer spring tension (5). and screw cap hexagon (4) and tighten.2.Install cover (7), washer flat (6), washer spring tension (5) and screw cap hexagon (4) and tighten.Change 2 5-242