TM 9-6115-668-133. Check electrical function:a.Remove collar nut (12) on fuel line (6) from flame glowplug (11) pull fuel line (6) off flame glowplug (11 ), andPlug-b.On front panel of control cabinet unit, set MASTER SWITCH S1 to ON.c.On front panel of control cabinet unit, turn GLOWPLUG/START rotary switch to START and hold.NOTEIf voltage is <17 VDC or >22 VDC, perform troubleshooting as indicated in figure3-3.d.Use multimeter to measure DC voltage at cable 1X5 (13): should be approximately 1 SVDC.4. Check flame glowplug:a.Remove flame glowplug as instructed in steps 2. through 5.b. On front panel of control cabinet unit, set MASTER SWITCH S1 to ON.c.On front panel of control cabinet unit, turn GLOWPLUG/START rotary switch to START and hold.d.Install fuel line (6) and cable 1X5 (13) on flame glowplug (11).NOTEFuel must emerge from flame glowplug as engine turns over.lf no fuel emerges, replace flame glowplug (11).e.On front panel of control cabinet unit, set MASTER SWITCH S1 to ON.f. Turn GLOWPLUG/START rotary switch to START and hold.NOTEUse Hylomar when Inserting flame glowplug.1.Install flame glowplug (11) on turbocharger air duct (9) and tighten locknut (10).2.Install cable 1X5 (13) on threaded portion of flame glowplug (11) with washer (14) and nut (5).3.Install collar nut (12) on fuel line (6) to flame glowplug (11).4.Screw plug connector 1J13 (16) with cable onto pickup.5. Close flap (2).5-175