TM 9-6115-668-135.17CURRENT TRANSFORMER MAINTENANCE.This task covers:a. Removalb. InstallationGeneral Mechanic’s Tool Kit(item 2, appendix B)Automotive Fuel and Electrical System Repair, Tool Kit(item 3, appendix B)Load bank (item 19, appendix B)ReferenceGenerator Set 150 kW shutdownparagraph 2.5.2Cable ties(item 10, appendix E)WARNINGDisconnect the negative battery cable first and then the positive battery termi-nal cables. Failure to observe this warning could result in severe personal injuryor death.CAUTIONTag all cables prior to removal to ensure correct connection of the cables duringinstallation.1.Open flap (2, figure 5-32) on unit hood assembly (1).2.Open front panel (4) on control cabinet assembly (3) and secure with prop (5).3.Remove eighteen screws (6), eighteen serrated lock washers (7), and eighteen washers (8).4. Lower control cabinet connector panel (9) and prop.5. Remove current transformer T12 (36):NOTERemoval procedure for current transformer T5 (52), T6 (54), T7 (55), T8 (61), T9(62), T10 (63), T11 (47) and T13 (49) Is the same as for current transformer T12(36), described below.When removing current transformer T1 (57), T2 (64), T3 (65), T4 (66), alsoremove three plastic screws (59) and remove insulator strip (66).5-138Change 1
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business