page 4TM 9-6115-668-13 DANGEROUS VOLTAGE EXISTS ON LIVE CIRCUITS. AL- WAYS OBSERVE SAFETY PRECAUTIONS AND NEVER WORK ALONE. FAILURE TO OBSERVE THIS WARNING COULD RESULT IN SEVERE PERSONAL INJURY OR DEATH. NO Measure voltage at FlZIAi and IA2: 24 VDC? YES v Repair or Replace cables ‘41” and ‘0” v NO Measure voltage at YES - Ft2/98and K9IA2: - 24 VDC? w v Repair or Replace NO Measure voltage at YES cables ” 138” and “0” F12197 and K9lA2 FtPflt and T2 shorted: 0 VDC? FtZ/Tl and T2 open: 24 VDC? ‘I v Replace Ft2 Measure voltage at (PARAGRAPH 5.10) Figure S-17 GENERATOROVER TEMPERATURE lamp lights up during operation (sheet 2 of 4). 5 - 88