TM 9-6115666-13 DANGEROUS VOLTAGE EXISTS ON LIVE CIRCUITS. AL- WAYS OBSERVE SAFETY PRECAUTIONS AND NEVER WORK ALONE. FAILURE TO OBSERVE THIS WARNING COULD RESULT IN SEVERE PERSONAL INJURY OR DEATH. NO Measure voltage at YES - K27l21 and K14/A2, V9: _ 24 VDC? 7 Replace K27 (PARAGRAPH 5.7) 7 NO Measure voltage at - K21/3t and Kl4fA2. V9: 24 VDC? YES v Repair or Replace cable “63” 7 NO Measure voltage at YES K21/32 and Kl4/A2. V9: - 24 VDC? 7 Replace K2 1 (PARAGRAPH 5.6) 7 NO Measure voltage at YES Kl2i62 and K14lA2. V9: 24 VDC? Repair or Replace NO Measure voltage at YES - K12i61 and K14/A2, V9: - 24 VDC? 7 7 Replace Kl2 Continue on (PARAGRAPH 5.6) Page 6 Figure 5-9 AC CIRCUIT INTERRUPTER ON lamp does not iight up (sheet 5 of 11). 5-56