paragraph 4.66TM g-6115-668-1 3 WAHNING r- Replace R 16 in Control Cabinet Assembly 1 NO DANGEROUS VOLTAGE EXISTS ON LIVE CIRCUITS. AL- WAYS OBSERVE SAFETY PRECAUTIONS AND NEVER WORK ALONE. FAILURE TO OBSERVE THIS WARNING COULD RESULT IN SEVERE PERSONAL INJURY OR DEATH. NO Measure voltage at YES K1414 and Kl/A2, V6: _ 24 VDC? T Repair or Replace cable “70” v NO Measure voltage at YES - Ki4/3 and KI/IU, V6: 24 VDC? v v Replace K14 NO Measure voltage at YES (PARAGRAPH 5.6) - R16. Kl/Ol and KlIA2, V6: - 24 VDC? v-v Repair or Replace NO Measure voltage at YES cable “72” RlG(Output) and Kt/AZ, V6: - 24 VDC? Figure 5-9 AC CIRCUIT INTERRUPTER ON lamp does not light up (sheet 8 of 77). 5-59