TM 9-6115-660-13&P5-20 PU-798A AND PU-799A GENERATOR MOUNTING RAIL MAINTENANCE.This task covers: a. Removalc. Installationb. RepairINITIALSETUPToolsEquipmentConditionsTool Kit, General Mechanic’sReference(item 1, appendix B)Rivet Gun (item 8, appendix B)Trailer handbrakes set, front supportleg/landing leg lowered, and rearMaterials/Partsleveling-support jacks lowered; paragraph2-3.2.1. Accessory box removed; paragraphRivets (items 8, 9, and 10, appendix I)4-19. Generator set removed; paragraph5-6. Center floor removed; paragraph5-16.1.REMOVALRemove rivets (1 and 2, figure 5-24) and mounting rail (3) from trailer chassis (4).REPAIRRepair of generator mounting rails consists of replacing rivets (5) and doubler plates (6 and 7), and rivets (8) andangle supports (9 and 10).INSTALLATIONPlace mounting rail (3) on trailer chassis (4) and secure with rivets (1 and 2).Change 2 5-43