TM 9-6115-659-13&PINSTALLATION1.Using the same sling as in removal step 8, attach sling to generator set lifting/tiedown rings.2.Using the same lifting device as in removal step 9, lift generator set (6) and position it on trailer.NOTEHardware holding generator sets on trailers differs between configurations. Wheninstalling generator sets, refer to figure 5-7 to determine hardware used. Position lockwashers as noted in disassembly.3.Install self-locking nuts (1, figure 5-7), flat washers (2), lock washers (4), and cap screws (3). Torque to 80-88 lb-ft(108.5-119.3 N•n).4.Position fender, splash guard, and switch box (as an assembly) on trailer chassis.5.Install four screws (8, figure 5-6), eight flat washers (9), and four self-locking nuts (10) in fender (12).6.Install three screws (5), six flat washers (6), and three self-locking nuts (7) in inboard edge of splash guard (11).7.Install cable clamps (4), screws (1), flat washers (2), and self-locking nuts (3).8.Insert power cable electrical leads and ground cable through generator set access opening from which generatoroutput plate was removed in removal step 1.9.Position generator output plate (2, figure 5-5, AN/MJQ-35, AN/MJQ-35A and AN/MJQ-36 only) with gasket (7) againstgenerator set housing (3). Secure with four cap screws (1), lock washers (4), and nuts (5).10. Refer to TM 9-6115-641-10 and connect power cable ends (6) to generator set load terminals as follows:(1) Lead marked L1 to L1(2) Lead marked L2 to L2(3) Lead marked L3 to L3(4) Lead marked LO to LO(5) Ground cable to GND terminalChange 2 5-14
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business