TM 9-6115-604-34
NAVFAC P-8-633-34
(8)
Test LOCAL REMOTE switch S2 in accordance with the Operator and Organizational Maintenance
Manual.
(a) lf the switch is good, then either watt transducer WMT, AC KILOWATTS meter Ml 07, or KILOWATT
HOURS counter CNTR is defective. Proceed with step (9), below.
(b) If the switch is bad, replace it in accordance with the Operator and Organizational Maintenance
Manual. Then start this test again, from the beginning.
(9)
Test AC KILOWATTS meter M107 and KILOWATT HOURS counter CNTR in accordance with the
Operator and Organizational Maintenance Manual.
(a) If either or both are bad, replace in accordance with the Operator and Organizational Maintenance
Manual. Then start this test again from the beginning.
(b) If both are good, then replace watt transducer in accordance with step j, below.
j.
Watt Transducer WMT Removal and Installation.
WARNING
Do not work on energized equipment Generator set must be shut down. Transducer voltage
and current Inputs and outputs are hazardous. Performing maintenance on energized
transducers may result In Injury or death.
(1)
Remove. See Figure 1 0-8.
(a) Tag and disconnect wires from watt transducer WMT.
(b) Remove screw and captive washer assemblies (9) to remove watt transducer WMT (1 0).
(2)
Install. See Figure 10-8.
(a) Install watt transducer WMT (10) and secure with screw and captive washer assemblies (9).
(b) Make wiring connections to watt transducer terminals as tagged. Remove and discard tags.
10-25/( 10-26 blank)