5-23. GENERAL.
The applications kit provides the MEP113A generator set with remote control of the emergency stop and
battle short capabilities, and remote low fuel monitoring. The kit consists of a connector plate, remote housing
assembly, cable harness assembly, and electrical tiedown straps.
NOTE
Remove the application kit before generator set is forwarded for depot maintenance.
Application kit must be retained for installation on replacement generator set.
5-24. TROUBLESHOOTING.
Table 5-3 contains a list of malfunctions which is useful in diagnosing and correcting unsatisfactory
operation or failure of the applications kit. Each malfunction is followed by a listing of probable causes. The
corresponding listing of corrective actions references the applicable maintenance paragraph for the necessary
procedures.
NOTE
Refer to the Operator and Unit Maintenance Manual for troubleshooting information
applicable to lower levels of maintenance.
5-25. APPLICATIONS KIT INSTALLATION AND REMOVAL.
a. Installation.
WARNING
Before maintenance, shut down AC power. Shut down DC power by removing the
generator set battery cable from the negative terminal (). High voltage will cause
death and/or burns. Open all doors and allow generator set to cool. Excessive heat will
also cause burns.
(1) Connector Plate.
(a)
(b)
(c)
(d)
Remove plug and sleeve assembly (1, figure 5-23) by removing six capscrews (2) and
Iockwashers (3) securing plate to generator housing. (Refer to the Operator and Unit Maintenance
Manual for procedures.)
Remove four corner capscrews and Iockwashers from cover plate leaving two center capscrews
securely fastened to plate.
NOTE
Place the four capscrews and Iockwashers in the marked bag supplied with the
applications kit and store in the generator set tool stowage compartment.
Mount plate and sleeve assembly (1, figure 5-24) over cover plate (2). Secure using four
capscrews (3), Iockwashers (4), and spacers (5) provided with applications kit.
Feed cable harness assembly (1, figure 5-25), attached to connector plate assembly (2), through
the opening made by the removal of plate and sleeve assembly.
5-52