ARMY TM 9-6115-464-34
AIR FORCE TO 35C2-3-445-2
NAVY NAVFAC P-8-624-34
1.
2.
3.
4.
5.
6.
NOTES:
ALL SOLDERED CONNECTIONS SHALL BE IN AC-
CORDANCE WITH MIL-STD-454, REQUIREMENT 5.
INSTALL STRAPS, FIND NO. 5 AT 3.0 MAX.
INTERVALS.
WIRE MARKING TO BE IN ACCORDANCE WITH
MIL-W5088 EXCEPT THAT LENGTH BETWEEN
GROUPS OF NUMBERS SHALL NOT EXCEED 6
INSTALL END SEAL PLUGS, FIND NO. 4 ON UNUS-
ED HOLES OF CONNECTORS FIND NO. 1 AND 2.
INTERPRET DRAWING PER MIL-STD-100.
REFERENCES:
a) FOR ELECTRICAL WIRING DIAGRAM, SEE
DRAWING 722205.
b)-FOR SCHEMATIC DIAGRAM, SEE DRAWING
72-2200 AND 722269 FOR PRECISE, 72-2295
AND 72-2277 FOR UTILITY
Figure 3-89. Special Relay Assembly to Static Exciter Assembly Wiring Harness, Drawing No. 72-2220
3-197
INCHES