ARMY TM 9-6115-464-12
AIR FORCE TO 35C2-3-445-1
NAVY NAVFAC P-8-624-12
1-11 IDENTIFICATION AND TABULATED DATA.
a.
Identification. There are eleven major identification and instruction plates on the generator set.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
Generator Set Identification Plate. Located at the top left side of the front housing assembly. Specifies
nomenclature, model number, serial number, stock number, contract number, engine serial number,
manufacturer, and shipping weight and dimensions.
Generator Set Rating Plate. Located at top left side of front housing adjacent to generator set identifica-
tion plate. Specifies kilowatt capacity relative to altitude and temperature, hertz rating, rated voltages and
phases, voltage adjustment ranges, power factor, type, class, mode and size.
Fuel System Diagram Plate. Located on inside face of left side generator compartment access door.
Contains diagram of fuel system.
Operating Instruction Plate. Located on inside face of right hand control panel-access door. Speci-
fies prestart checks, starting sequence, stopping sequence, and instructions for parallel operation.
Schematic and Troubleshooting Diagram Plates. Troubleshooting plate is located on inside face of
right and left engine compartment doors. A schematic diagram plate is located on the inside of the
battery doors of the power generation and control circuits.
Wlnterization System Diagram and Caution Plates (furnished with Winterization Kit). Installed on in-
side face of left rear upper control and lower left vent door. Specifies installation and operation of
winterization systems. Also includes cautions pertinent to operation of winterization kits.
Lifting and Tie-Down Attachment Information Plate. Located on lower right gear generator compart-
ment door. Specifies center of gravity, tie-down location, lifting shackle location and capacity and
direction of travel.
Battery Reconnection Instruction Plate. Located inside face of battery compartment access door. Con-
tains diagram of battery installation and specifies cautions to be observed when replacing batteries.
Generator Identification Plate. Located on upper right side of generator housing. Specifies nomencla-
ture, part number, style, rated rpm, frequency, serial number, kva rating, P/F, ampere rating, voltage,
and manufacturer.
Engine Identification Plate. Located on left side of engine block. Specifies manufacturer, manufac-
turers specification, model number, serial, date of manufacture, bore, stroke, displacement, maxi-
mum continuous speed, maximum set continuous brake horsepower, lube oil pressure, firing order,
intake and exhaust valve tappet clearances, and military specification.
Voltage Reconnection Plate. Located on terminal guard over voltage reconnection board. Contains
instructions for reconnecting the generator from 120/208 to 240/416 volts and reconfiguration back
to 120/208 volts.
b. Tabulated Data.
(1) Engine Generator Set (End Item).
Model Numbers:
50/60 Hz Tactical Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. MEP-004A
50/60 Hz Tactical Precise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. MEP-103A
400 Hz Tactical Precise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . .. MEP-113A
1-7