TM5-6115-634-14&PNAVFAC P-8-647-14&PT0-35C2-3-445-14TM-6115-148P/14-32. REPLACE FILTER ELEMENT (cont)SERVICESERVICE THE FILTER ELEMENT.a. Soak and agitate filter elementfor 15 minutes in a solution ofwarm water and mild detergent.b. Rinse filter element until cleanand air dry.c.The filter element may also becleaned with low pressure(30 psig max) compressed air.INSTALLATIONINSTALL FILTER ELEMENT.Place the filter (5) intoposition on the air filterhousing (6), and installretaining bar (4) with twoscrews (1), lockwashers (2)and nuts (3).NOTEFOLLOW ON MAINTENANCE:Negative Battery CableRepl ace(Para. 4-10).4 - 5 0