TM-6115-634-14&P
NAVFAC P-8-647-14&P
T0-35C2-3-445-14
TM-6115-14&P/1
4-28 REPLACE AIR CLEANER HOUSING (cont)
4. INSTALL AIR INLET HOSE.
a.
Place the metal clamp (2) over
the air inlet hose (1) approxi-
mately one-inch from the end.
b. Fit the air inlet hose (1) onto
the air cleaner housing air
inlet pipe, and secure air
inlet hose (1) by moving the
clamp (2) over the air inlet
pipe and tightening the clamp
(1).
NOTE
FOLLOW ON MAINTENANCE:
Replace Fault Indicator Panel
(TM5-6115-464-34, Para. 4-3).
Install Filter Element (Para.
4-32).