TM5-6115-634-14&PNAVFAC P-8-647-14&PT0-35C2-3-445-14TM-6115-14&P/1MAINTENANCE AIR CLEANER SYSTEM4-28. REPLACE AIR CLEANER HOUSINGThis task covers: a. Removalb. InstallationINITIAL SETUPToolsGeneral Mechanic’s Tool Kit5180-00-177-7033Materials/PartsFilter Housing97403-13338E1894EquipmentConditions:ReferencePara. 4-32 Remove Filter Element.TM5-6115-464-34Remove Fault Indicator PanelPara. 4-3.REMOVALGeneral Safety InstructionsTo avoid dropping the air filterhousing, get help to hold thehousing in place while removingor replacing the top mountinghardware.1.2.3.REMOVE AIR INLET HOSE.To remove air inlet hose (1),loosen clamp (2). Pull airinlet hose from back of aircleaner housing (3).REMOVE AIR BREATHER HOSE.To remove air breather hose(4), depress spring clamp (5)and remove hose from rear ofair cleaner housing (3).REMOVE SWITCH PRESSURE.Remove cannon plug (6) fromthe pressure switch (7) andremove the pressure switch byunthreading.4-40