TM 5-6115-593-12
TO 35C2-3-463-1
STEP
1.
CHECK LUBRICATING COOLANT LEVELS.
STEP
2.
CHECK AIR BOX DAMPER POSITION AND RESET MANUALLY TO OPEN (SEE DETAIL A) IF REQUIRED.
STEP
3.
CHECK BATTERY TERMINALS, MINUS (-) TO GROUND.
STEP
4.
PLACE 24V DC CONTROL CIRCUIT BREAKER TO ON POSITION ON GENERATOR PANEL.
STEP
5.
ENSURE MAINTENANCE SWITCH IS IN OPERATION POSITION ON AC-DC CONTROL PANEL.
STEP
6.
CHECK FUEL LEVEL BY PLACING BATTLE SHORT SWITCH IN THE ON POSITION ON GENERATOR PANEL AND THEN THE
MASTER SWITCH IN START POSITION ON ENGINE PANEL.
STEP
7.
RETURN MASTER SWITCH TO STOP AND THEN THE BATTLE SHORT SWITCH TO OFF.
STEP
8.
CHECK ENG FAULT INDICATORS AND ANNUCIATOR BY PLACING ANNUCIATOR TEST SWITCH IN TEST POSITION ON
GENERATOR PANEL. IF NONE OF THE LIGHTS ARE ON AFTER BEING TESTED, PROCEED WITH THE NEXT STEP. IF A
LIGHT DOES NOT COME ON, CORRECT THE INDICATED FAULT BEFORE PROCEEDING.
STEP
9.
CHECK VOLTAGE AND FREQUENCY REQUIREMENTS OF THE LOAD AGAINST THE VOLTAGE AND FREQUENCY
CONNECTION OF THE SET.
STEP
10.
PLACE AUTO/TRIP/MAN SWITCH IN MAN POSITION.
Figure 2-5. Preparation for Starting (Sheet 1 of 3)
2-12