TM5-6115-585-12
NAVFAC P-8-262-12
TO - 35C2 - 3 - 455 - 1
TM-05684C-12
Section II. MOVEMENT TO A NEW WORKSITE
4-3.
a.
DISMANTLING GENERATOR SET FOR MOVE-
(6) On ASK equipped generators, remove batteries access
M E N T .
door. Disconnect negative battery cable from battery.
Preparation for Movement.
(7) Disconnect any other hoses, lines or cables,
if used.
(1) Disconnect the load cables.
(8)
(2) Remove exhaust pipe extension if used.
Close and secure all doors and panels.
b. Movement. Preferred means of movement is to
(3) Make certain vent on underside of fuel filler
t r a n s p o r t . T o w i n g f o r s h o r t d i s t a n c e s i s p e r m i s s i b l e
cap is closed.
if terrain is suitable.
(4) Refer to the Items Troop lnstalled or Author-
ized List (Appendix B and make sure all items are on
4-4. R E I N S T A L L I N G G E N E R A T O R S E T A F T ER
the equipment.
MOVEMENT.
(5) Disconnect the ground lead from the ground
Refer to paragraph 4-2 for reinstallation after move-
stud.
ment to a new worksite.
Section
III.
REPAIR
PARTS;
SPECIAL
TOOLS;
SPECIAL
TEST,
MEASUREMENT
AND DIAGNOSTIC EQUIPMENT AND SPECIAL SUPPORT EQUIPMENT
4-5. SPECIAL TOOLS AND EQUIPMENT.
4-6. MAINTENANCE
REPAIR
PARTS.
Special tools are listed in Appendix C, section III.
Repair parts and equipment are listed and illustrated
i n t h e r e p a i r p a r t s a n d s p e c i a l t o o l s l i s t m a n u al
covering organizational maintenance for this Gener-
ator Set.
Section IV. LUBRICATION INSTRUCTIONS
4-7. L U B R I C A T I O N .
a. Lubrication Order. Lubrication instructions for
the Generator Set are contained in L05-6115-585-12.
( 5 ) O p e n d r a i n p l u g ( 1 , f i g u e 4 - 3 0 ) a n d d r a i n
o i l f i l t e r o i l i n t o a c o n t a i n e r h a v i n g a t l e a s t a 1
q u a r t c a p a c i t y.
( 6 ) R e m o v e t h r o u g h b o l t ( 2 ) a n d p u l l o i l f i l t er
(F) Air Force lubrication instructions appear in the
a p p l i c a b l e w o r k c a r d s e t i n t h e T O 3 5 C 2 - 3 - 1 - 4 2 6
s e r i e s .
body (3) loose from oil filter adapter (5).
( 7 ) D i s c a r d g a s k e t ( 4 ) a n d o i l f i l t e r e l e m e nt
( 6 ).
b. Oil Change (see figure 3-20). On ASK equipped generators,
remove oil access door.
(1) With drain valve closed, disconnect oil drain
hose from the plug on the skid-base.
(2) Open drain valve and drain oil into a con-
tainer having at least a 7 quart capacity.
(3) Close drain valve.
(4) Connect oil drain hose to plug on skid-base.
4-4
C h a n g e 8
(8) Wipe inside of oil filter body (3 clean with a
r a g.
( 9 ) W i p e i n s i d e o f a d a p t e r ( 5 ) c l e a n w i t h a
r a g . I n s u r e t h e g a s k e t g r o o v e i s f r e e o f f o r e i gn
m a t e r i a l . I n s p e c t g a s k e t s ( 7 ) a n d ( 1 0 ) t o b e s u re
they are not torn or frayed. Check that retainer (8),
a n d s p r i n g ( 9 ) a r e n o t d e f o r m e d . R e p l a c e d a m a g e d
c o m p o n e n t s.