TM 5-6l15-445-34
TO35C2-3-446-2
NAVFACP-8-625-34
TM06858B/06869D-34
[1] Position voltage ad-lust rheostat R2 on
(4) PIace the operation switch on the genera-
generator set control cubicle to the approximate
tor set control cubicle in the PARALLEL position.
midpoint.
(5) Adjust reactive current adjust potentiometer
R29 of the special relay assembly to provide a special
[2] Refer to the Operator and Organiza-
droop of 3 percent.
tional Maintenance Manual and start the generator
set.
(6) Adjust the load sharing adjust rheostat (R28)
of the precise relay assembly until 4 to 6 volts
[3] Adjust voltage rheostat variable resis-
appear across pins A and B of the paralleling recept-
tor R2 to obtain generator assembly rated voltage.
acle.
Paralleling Adjustments.
c"
[1] Refer to the Operator and Organiza-
NOTE
tional Maintenance Manual and connect a rated
load to the generator set load terminal board.
Step (6) pertains to precise generator sets
only.
[2] Start the generator set and operate at
Full rated load.
(7) Refer to the Operator and Organizational
Maintenance Manual and shut down the generator
set.
Section IV.
GENERATOR ASSEMBLIES
5-15. GENERAL.
washer (2) to remove drip cover (3).
remove screen guard (6).
remove lead block assembly (9) and gasket (10).
NOTE
Tag electrical leads to insure proper posi-
tioning at installation loosen clamping
screws to relieve tendon on the leads.
5-16. GENERATOR MAINTENANCE INSTRUCTIONS.
(5) Remove screws (11) and lockwashers (12)
to remove screen guard (13).
erator removal procedure.
(6) Remove screws (14) and lockwashers (15)
b. Diassembly.
to remove cover plate (16).
(1) Diassemble generator by following the as-
(7) Remove plug (17), screw (18) and lock-
cending sequence of index numbers assigned to figure
washer (19).
5-36 only as
required to
replace damaged or
defective
components.
(8) Remove screws (18) and lockwashers (21).
Using a suitable puller, remove bearing housing (22).
Change 4
5-55