TM 5-6115-465-12
TO 35C2-3-446-1
NAVFAC P-8-625-12
b. Cleaning and Inspection.
remove starter from bell housing.
(1) Clean receptacle with filtered compressed
b.
air and a soft bristle brush.
Cleaning and Inspection.
(2) Clean receptacle box with a clean, lint-free
(1) Clean starter assembly with a clean,
cloth moistened with an approved solvent.
lint-free cloth moistened with an approved solvent.
(2) Inspect starter assembly for cracks,
(3) Inspect receptacle for bent or broken pins,
stripped terminal threads, corrosion or other dam-
corrosion, evidence of shorting and other damage.
age.
(3) Inspect solenoid assembly for cracks,
(4) Inspect wiring of receptacle for frayed or
corrosion, evidence of shorting and other damage.
deteriorated insulation, evidence of shorting and
(4) Inspect all threaded parts for stripped or
other damage.
damaged threads.
(5) Inspect receptacle box for dents, corro-
c.
Repair.
sion and other damage.
(1) Brush replacement.
(6) Replace any parts damaged beyond simple
repair.
NOTE
c. Installation. Install slave receptacle in
It is not necessary to remove the starter
reverse order of removal procedures.
assembly from the engine to replace the
brushes.
a.
Removal.
(1) Tag and disconnect electrical leads to