P-8-627-34
T.O. 35C2-3-442-2
TM-07464A-35
TM 5-6115-457-34
c. Inspect switch assembly inside of
is actuated while the actuator plate is de-
cap and cover assembly (6) for quality of
pressed to its lower limit. If third click
is not indicated, reset manual reset button.
solder connections on switch terminals.
Check for corrosion on switch terminals.
Replace cover assembly (6) if switch/or
switches are defective.
d. Inspect for freedom of movement of
switch contact actuator plate. Depress
actuator plate with thumb on center of
e. Inspect inside of body assembly for
actuator plate. There should be a total of
signs of moisture or corrosion.
three separate clicks as each micro switch
8-26A/(8-26B Blank)
Change 8