P-8-627-34
T O 35C2-3-442-2
TM-0746U-35
TM 5-6115-45734
missive paralleling relay (K16), in position
2. Inspect harness connectors for
using four each, screws.
damaged threads; bent, loose or missing
pins and for shorts.
e. Assemble battery charging am-
meter shunt (R13), engine cracking relay
6 - 1 3 3 . REPAIR.
into position using two each, screws and
nuts.
a. Repair or fabricate mode II relay
WARNING
box assembly wiring harness according to
Avoid breathing fumes generated -by
tection is required.
6. Straighten dented or distorted sheet
metal parts using proper tools. Blend in
f. Connect wire harness loads to com-
repaired area with a suitable abrasive
paper and touch up painted surfaces. Re-
stencil panel markings as necessary.
NOTE
6-134. REASSEMBLY. Refer to figure
6-34 and reassemble the mode II relay box
Solder connections shall be made
assembly in reverse order of index num-
using solder, Federal Specification
bers assigned. Pay particular attention
QQ-S-571, Sn 60.
to the following:
g. Test mode II relay box assembly as
a. Install wire harness (23) in chassis
(39) and secure in position with four
screws and nuts at each of the ten connec-
tors.
chassis assembly (39) using ten screw
assemblies (2) and washers (3).
b. Assemble electronic components
assembly (A6) in position using three
6-135. INSTALLATION. Refer to figure
6-15, and install the mode II relay box
assembly. Secure the assembly in posi-
tion using four screws and nuts. Refer to
c. Assemble dc control relay assembly
the Operator and Organizational Mainte-
(A5) in position using four nuts.
nance Manual and reconnect all electrical
plug connections to the assembly
d. Assemble underfrequency relay
(K12), undervoltage relay (K11) and per-
Change 8
6-102