P-9-TM-457-35
T.O. 35C2-3-442-2
TM 5-6115-457-34
TM-07464A-35
Table 2-3. Troubleshooting (Continued)
PROBABLE CAUSE
CORRECTIVE ACTION
MALFUNCTION
a. Intermittent or high
a. Clean, retighten, or re-
rate low or unsteady.
place defective parts.
or ground return cir-
cuits or battery connec-
tions.
b. Defective regulator.
b. Replace if defective
c. Alternator rectifier
diodes shorted or open.
d. Replace rotor
coil) turns grounded or
shorted.
e. Tighten connections.
Loose connections on
e.
alternator and/or
regulator.
f. Defective brushes.
f. Replace brushes
a. Misaligned belt or
a. Align drive pulley and
pulley.
alternator pulley and
belts.
b. Loose pulley.
b. Tighten pulley nut, if key-
way is worn, replace
d. Shorted rectifier
d. Replace diode assembly
diodes.
2-51