Figure 3-53. Cylinder Block Assembly, Exploded View
Figure   3-55.   Thermal   Watt   Converter   Circuit   Schematic

TM-9-6115-464-34 Generator Set Diesel Engine Driven Tactical Skid Mtd 15 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Page Navigation
  161    162    163    164    165  166  167    168    169    170    171  
ARMY TM 9-6115-464-34 AIR FORCE 35C2-3-445-2 NAVY  NAVFAC  P-8-624-34 Section   Vlll.   MAINTENANCE   OF   GENERATOR   SET   CONTROLS 3-58.  GENERAL. This section contains maintenance instructions for the generator set controls. The control cubicle assembly and sensing  monitors  contain  the  controls,  instruments  and  indicators  for  controlling  and  monitoring  the  operation  of the generator set. Precise models of the generator set incorporate a governor control unit which signals the actuator unit to change the fuel injection pump governor setting which controls engine speed and, thus, generator frequency. This function is assumed by the manual speed control on utility models. The interconnecting wiring harnesses provide electrical connection between major assemblies and the control cubicle and fault locating indicator. 3-59. CONTROL CUBICLE ASSEMBLY. a. Frequency Meter and Transducer. (1) (2) (3) (4) (5) (6) (7) (8) Refer to the Operator and Unit Maintenance Manual and remove, clean, and inspect frequency meter  and  transducer. Install frequency meter and transducer in a test setup as shown in figure 3-54. NOTE Test frequency meter must have an accuracy of 0.05 percent. Activate sinusoidal source and adjust its output as indicated by the test frequency meter to the lowest frequency indication on the frequency meter being tested (388 Hz for a 400 Hz frequency meter and 48 Hz for a 50/60 Hz frequency meter). Rotate adjusting screw of frequency meter being tested until its indication exactly matches that of the test frequency meter. If the frequency meter being tested cannot be properly adjusted, replace it and the frequency transducer. When frequency meter being tested has been properly adjusted, slowly increase the sinusoidal source frequency to the highest value of the frequency meter being tested (412 Hz for a 400 Hz frequency meter and 62 Hz for a 50/60 Hz frequency meter). If at any point the indication of the frequency meter being tested varies more than 0.25 percent from that of the test frequency meter, replace both transducer and frequency meter being tested. Refer to the Operator and Unit Maintenance Manual and install frequency meter and transducer. b. Kilowatt Meter and  Thermal  Converter. (1) Refer to the Operator and Unit Maintenance Manual and remove, clean, and inspect kilowatt meter and  thermal  converter. (2)  Test  ac  kilowatt  meter  and  converter  as  follows: (a) Connect a calibrated kilowatt meter and a suitable variable load to the generator set load terminal board. (b) Refer to the Operator and Unit Maintenance Manual and start the generator set. 3-130







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.