TM 9-6115-668-135.15 SAFETY DEVICE N3 MAINTENANCE.This task covers:a. Removalc. Adjustmentb. Repaird. InstallationToolsEquipmentConditionsGeneral Mechanic’s Tool KitReference(item 2, appendix B)Generator Set 150 kW shutAutomotive Fuel and Electrical System Repair, Tool Kitdown,(item 3, appendix B)paragraph 2.5.2Load bank (item 19, appendix B)X/Y-printer (item 16, appendix B)Materials/PartsCable ties(item 10, appendix E)WARNINGDisconnect the negative battery cable first and then the positive bat-tery terminal cables. Failure to observe this warning could result in se-vere personal injury or death.CAUTIONTag ail cables prior to removal to ensure correct connection of the cablesduring installation.REMOVAL1.Open flap (2, figure 5-31) on unit hood assembly (1).2.Open front panel (4) on control cabinet assembly (3) and secure with prop (5).CAUTIONDo not useexcessive force to removecircuit boards. Note the positionof circuit boards during removal for correct positioning during instal-lation.3. Remove circuit boards from safety device N3 (6):a. Remove four screws (11), four serrated lock washers (12) and four washers (13), two anglepieces (14) and front panel (15) from housing (10).5-126