paragraph 4.44TM 9-6115-666-13 DANGEROUS VOLTAGE EXISTS ON LIVE CIRCUITS. AL- WAYS OBSERVE SAFETY PRECAUTIONS AND NEVER WORK ALONE. FAILURE TO OBSERVE THIS WARNING COULD RESULT IN SEVERE PERSONAL INJURY OR DEATH. NO Measure voltage at YES - K7lAl and K7/AZ: - 24 VDC? ‘I Repair or Replace cable “49” v NO Measure voltage at YES - K7/23 and HBlX2: 13 - 27.5 VDC? t Repair or Replace cables “94” and “0” NO v Measure voltage at YES K71’24 and H8/X2: - 13 - 27.5 VDC? v Replace K7 (PARAGRAPH 5.7) ‘I Measure voltage at Figure 5-75 UNDER/OVER FREQUENCYlamp lights up during operation (sheet 6 of 6). 5 - 80