TM 9-6115-668-13
4.5 INSTALLATION INSTRUCTIONS.
Refer to paragraph 2.3.5
4.6 PRELIMINARY SERVICING AND ADJUSTMENT OF EQUIPMENT.
CAUTION
At temperatures below 32° F (0 ° C), if the batteries are not fully charged
they will be damaged or destroyed.
4.6.1 Batteries.
The batteries in the battery set assembly are maintenance free.
No electrolyte can leak out during proper operation; there is no need to top up with distilled water;
The batteries exhibit very little self-discharge, so there is no need for frequent recharging to make
up for self-discharge losses.
4.6.2 Fuel Tank.
Fill fuel tank (paragraph 2.3.4) with fuel type in accordance with table 4-1. Fuel tank capacity is 101.7 gal-
ions (385 liters).
Table 4-1 Fuel
AMBIENT TEMPERATURE
DIESEL FUEL
+20 °F TO +120 °F (-6 °C TO 49 °C)
W-F-800 GRADE DF-2, JP4, JP5, OR JP8
0 °F TO +20 °F (-17 °C TO -6 °C)
W-F-800 GRADE DF-1, JP4, JP5, OR JP8
-25 °F TO 0 °F (-32 °C TO -17 °C)
W-F-800 GRADE DF-1
-25 °F TO 0 °F (-32 °C TO -17 °C)
W-F-800 GRADE DF-A
4-12