TM 9-6115-662-13&P2-7.4 Disconnect External Fuel Source. Disconnect auxiliary fuel hose as follows:a.b.c.d.Disconnect the auxiliary fuel hose from the generator set external fuel supply connector. Elevatethe free end of the auxiliary fuel hose to drain fuel back into the external fuel source. Place freeend of auxiliary fuel hose on a clean surface.Disconnect auxiliary fiel hose from fitting on container adapter (2, figure 2-17).Store auxiliary fuel hose in the generator set storage compartment located behind the batteryaccess door.Remove extension pipe (4), pipe (3), adapter (2), and strainer clamp (1) and store in the accessorybox.Figure 2-17. Auxiliary Fuel Source (Typical).2-49
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business