ARMY TM 9-6115-604-12NAVY NAVFAC P-8-633-12d.Replace.(1) Install the manual fuel shut off valve (2) in the fuel junction block on the engine, and reconnect thefuel discharge hose (3) to the manual fuel shut off valve (2).(2) Install the control cable to its attachment point on the generator set housing, to the emergencyshutdown lever, and to the emergency cable mounting bracket (4). Anchor the control cable at oneor more points along its length.e.Repair. Repair of the manual fuel shut off valve (2) is limited to ensuring that the control cable is properlyrouted and anchored, and to replacement of the push/pull emergency control, control cable,and the manual fuel shut off valve.4-54.INSPECT FUEL MANIFOLDS.The fuel manifolds are common points of pressurized fuel which provide fueldelivery to both cylinder banks.a.Inspect all fuel lines, manifolds, and fuel block (5, 13, and 24, figure 4-40) for cleanliness andevidence of leakage.b.Inspect condition of right bank fuel supply tube (17), right bank fuel drain tube (18), left bank fuel draintube (19). and left bank fuel supply tube (20).c.Fuel block connections (5, 13, and 24) should be securely mounted.d.Fuel manifold assemblies (27 and 30), machine thread pipes (3 and 28), and fuel manifolds (29 and 31)should be securely mounted and free of any damage.4-113