ARMY TM 9-6116-464-34
AIR FORCE TO 35C2-3-445-2
NAVY NAVFAC P-8-624-34
(11) Replace damaged connectors and terminals by unsoldering and removing electrical leads. Install
replacement part, make mechanical connection and solder in accordance with established
procedure.
(12) Replace defective wires using wire conforming to Military Specification MIL-W-5086, Type Il.
(13) Inspect housing for cracks, warping, and corrosion.
(14) Inspect all threads for crossing, stripping, and other damage.
(15) Replace all damaged or defective parts.
d. Assembly.
(1) Install connector (20, figure 5-1), screws (19), nuts (18) on housing (21).
(2) Install screws (13) in housing (14).
(3) Install indicator light base (17), tooth lockwasher (10), nut (8), lamp (7), and lens (6) on panel
assembly (9).
(4) Install circuit breaker (16), Iockwasher (5) and nut (4).
(5) Install key washer (11), on-off switch (15), tooth Iockwasher (3) and nut (2).
(6) Position panel assembly (9), and install screws (1).
e. Installation. Refer to the Operator and Unit Maintenance Manual for fuel burning winterization heater
control assembly installation instructions.
5-6