Cleaning. Inspection. and Testing
ELECTROMAGNETIC INTERFERENCE CAPACITORS
TM-9-6115-464-34 Generator Set Diesel Engine Driven Tactical Skid Mtd 15 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Page Navigation
263
264
265
266
267
268
269
270
271
272
273
ARMY TM 9-6115-454-34
AIR FORCE 35C2-3-445-2
NAVY NAVFAC P-8-624-34
(1)
(2)
(3)
(4)
(5)
(6)
(7)
If removed, install mounting brackets (17, figure 3–108) flat washers (16), screw and washer
assemblies (15).
Install cross-current compensation
transformer
(14), Iockwashers (13), screws (12), and nuts (11).
Install
instrumentation
transformer (10), flat washers (9) screw and washer assemblies (8).
If removed, install mounting bracket (7), flat washers (6) screw and washer assemblies (5).
Install current boot transformer (4), screws (3), Iockwashers (2) and nuts (1).
Route generator leads through
transformer
windows (noting polarity) as shown in figure 3-107; then
connect the wires and remove tags.
Connect electrical leads to transfer winding terminals.
Figure 3-109. Current Transformer Test Point