ARMY TM 5-6115-633-14&P
Administrative Storage.
1-8.
a.
Army equipment placed in administrative storage will have preventive maintenance performed in
accordance with the PMCS tables before storage. When equipment is removed from storage, PMCS will
be performed to ensure operational readiness.
b.
(F) For administrative storage procedures for Air Force equipment, refer to TO 35-1-4, Processing and
Inspection of Aerospace Ground Equipment for Storage and Shipment.
19.
Preparation for Shipment and Storage.
a.
(A) Army - Referto TB 740-97-2.
b.
(F) Air Force - Refer to TO 35-14 for component of end item generator sets and TO 38-1-5 for installed
engine.
Section Il. DESCRIPTION AND DATA
1-10.
Description. Power Plant AN1MJQ-18 is made up of two Tactical Utility Generator Sets, DOD Model
MEP003A, mounted on a single modified M103A3 trailer. These generator sets are air-cooled, diesel
engine-driven units, each with a load capacity of 10 KW at 60 Hz. The trailer is a two wheeled unit with a 11/2ton
carrying capacity. The modifications to the basic trailer provide stowage for the accessories and all equipment
necessary for mobile operation as well as providing a work platform for the operator and maintenance personnel.
Output from the power plant is applied to the system or equipment being powered through a switch box. The
AN/MJQ18 is supplied with either a 4wire or a 5wire configuration switch box. Figures 11 and 12 illustrate the
power plant with the fitted cover removed to show the generator sets.
1-2
Change 2