TM 5-6115-584-34
NAVFAC P-8-622-34
T0-35C2-3-456-2
Table 6-6. Testing Bridge Assembly
Check Resistance in Both
To Test Diode
Directions Between Terminals
A4-CR1
A4-CR2
A4-CR3
A4-CR4
A4-CR5
A4-CR6
c. Removal.
2-5
1-5
3-5
2-4
1-4
3-4
(1) Reconnection Switch (S6) and Transformers (CT1 and
CVT1). Due to the large number of wires connected to these
items, they are removed from the control box with the wiring
connected. Remove screw (3, figure 6-10) and lockwashers (4).
Remove screws (5), nuts (8), lockwashers (7) and spacers (6).
Remove switch (1) and wiring. Remove transformers (6 and 7,
figure 6-9) by removing screws(l), nuts(3) and lockwashers (2).
Tag and remove wiring from transformers and switch.
Disassemble transformers by removing screws(4) and nuts(5).
(2) Load Terminal Board (TB1) (see figure 6-9). Disconnect
load from load terminal board. Remove six screws (8) and
lockwashers (9), attaching board (10) to control box (24) and
remove board. Tag and disconnect four wires to load terminals
(25).
(3) AC Circuit Breaker (CB1). Remove side access panel
(13, figure 6-9) by removing screws (11) and lockwashers (12).
Tag and remove leads connected to circuit breaker (9, figure
6-10). Remove six screws (10) attaching breaker (9) to front
panel (2) and remove breaker.
(4) 15 Amp Circuit Breaker (CB3) (see figure 6-10). Remove
side access panel (13, figure 6-9). Tag and disconnect two elec-
trical leads to 15 amp circuit breaker (11, figure 6-10). Remove
TM-0568C-34
two screws (12) attaching breaker to front panel of output con-
trol box (2) and remove breaker.
(5) Convenience Receptacle (J14). Remove four screws (11,
figure 6-9) and lockwashers (12) attaching side access cover (13)
to output control box and remove cover. Remove four screws
(14, figure 6-10) and nuts (15) attaching receptacle cover to front
panel and remove cover (16) and gasket (17). Tag and discon-
nect two leads from receptacle. Remove two screws (18) and
nuts (19) attaching receptacle to front panel and remove recep-
tacle (13). Disconnect two leads from the receptacle and tape
each lead end, separately (figure 1-7).
(6) Linear Reactor (L1) (see figure 6-9). Remove side ac-
cess panel (13). Tag and disconnect six leads to linear reactor
(15). Remove four screws (14) attaching reactor to side panel
of output control box and remove reactor.
(7) Connector Assemblies (see figure 6-9). Remove screws
(16 and 19) and nuts (17 and 20) attaching connectors (18 and
21) to output control box and remove connector. Tag and discon-
nect wires from wiring harness to connector. Reconnect tagged
wires to new connector.
(8) Bridge Rectifier Assembly (see figure 6-9). Tag and
remove leads to rectifier assembly (23). Remove nuts (22)
holding bridge assembly to ac output control box and remove
bridge assembly. Replace bad diodes or resistors as necessary.
d. Install.
(1) Load Terminal Board (TB1). Attach four tagged wires
to load terminals per wiring diagram, figure 1-7. Attach load
terminal board (10, figure 6-9) to control box (24) with six screws
(8) and lockwashers (9).
(2) AC Circuit Breaker (CB1) (see figure 6-10). Attach cir-
cuit breaker (9) to front panel of output control box with six
screws (10). Attach six tagged leads to terminals 3,4,7,8, 11,
and 12 of breaker per wiring diagram, figure 1-1. Replace side
access panel.
(3) 15 Amp Circuit Breaker (CB3) (see figure 6-10). Attach
new breaker (11) to front panel of output control box (2) with
two screws (12). Attach two tagged leads to 15 amp circuit
breaker per wiring diagram, figure 1-1.
Change 4
6-17