Google+
Facebook
LinkedIn
Twitter
Digg
StumbleUpon
Home
Download PDF
Order CD-ROM
Order in Print
Table 1-2. Repair and Replacement Standards (Cont) - TM-5-6115-584-34_33
Figure 11. Generator set Electrical Schematic diagram
TM-5-6115-584-34 Generator Set Diesel Engine Driven Tactical Skid Mtd. 30 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Page Navigation
4
5
6
7
8
9
10
11
12
13
14
TM 5-6115-584-34
NAVFAC P-8-622-34
TO-35C2-3-456-2
TM-0568C-34
Table 1-2. Repair and Replacement Standards (Cont)
and Tolerances
Component
FLYWHEEL:
Face runout, total
Pilot bore eccentricity
FLYWHEEL HOUSING:
Attaching face deviation
Housing bore eccentricity
ROCKER ARM MECHANISM:
Tappet adjusting screw torque
CYLINDER HEAD:
Warpage (longitudinally)
Warpage (laterally)
Manufacturer Dimensions
Minimum
4 ft-lbs
Maximum
0.0053
0.0020
0.0113
0.005
10 ft-lbs
0.001
0.001
Maximum Allowable
Wear Limit
0.0015
0.0015
(7) Oil Cooler.
Refer to Operator and
m. Engine Repair and Replacement Standards. Table
Organizational Maintenance Manual.
1. Safety Devices.
(1) High temperature switch. Refer to Operator
and Organizational Maintenance Manual.
(2) Low oil pressure switch. Refer to Operator
and Organizational Maintenance Manual.
(3) Fuel level switch (day tank). Refer to
Operator and Organizational Maintenance Manual.
1-2 lists manufacturer’s sizes, tolerances, and maxi-
mum allowable wear and clearances.
n. Schematic Wiring Diagrams. Figure 1-1 shows
the schematic
wiring diagram
of the power plant.
o. Torque Values.
(1) Table 1-1 lists specific
torque
values.
(2) All
torque
values are calculated for oil lubri-
cated threads. Increase this value by 10 percent when
threads are not lubricated.
1-8