and current under load and varies the exciter field either upor down to keep the generator field at such a value as tomaintain constant alternator output voltage. The regulatedvoltage setting can be varied using the voltage adjustrheostat (R1).An ac receptacle (J14) is connected through a protectivecircuit breaker (CB3) to provide 120 VAC.Outputs from the voltage regulator (A2) transformed bytransforms (T1 and T2) to a value suitable for input tofrequency transducer (A3) which energizes frequency meter(M3).1-10. TABULATEDDATA.Identification and Instruction Plates (see figures 1-1and l-2).(1) Identification Plate.(a) Location. This plate is located on the sideof the control cubicle.(b) Content.US DEPARTMENT OF DEFENSEGENERATOR SET DIESEL ENGINE 5KW 60 HzMODEL: MEP 002ASER NO.:NSN: 6115-00-465-1044REG NO.:TM 5-6115-584-12TO-35C2-3-456-1NAVFAC P-8-622-12TM-05682C-12VOLTS: 120V 1 PH.120/240V 1 PH.120/208V 3PH.PF: 0.8AMPS: 52,26,17.3LG: 51 INW: 32 INHGT: 37 INDATE MFG:CONTR NO:WARRANTY:DATE INSP:MFD BY:TM 5-6115-584-12NAVFAC P-8-622-12TO-35C2-3-456-1TM-05682C-12(2) Operating Instruction Plate.(a) Location. This plate is located on the sideof the control cubicle.(b) Content.OPERATING INSTRUCTIONSHot refueling of generators while they are oper-ating poses a safety hazard and should not beattempted. Hot engine surfaces and sparks pro-duced from the engine and generator circuitryare possible sources of ignition. Severe injury ordeath to personnel and damage to the equip-ment may result.Ground set to avoid shock hazard.BEFORE STARTING SETNOTE: Push in DC CONTROL CIRCUITBREAKER. Pull manual governor controlthrottle all the way out and then push backin approximately halfway.1.Fill crankcase (do not overfill) and fueltank. Ensure that vent cap on underside ofthe fuel filler cap is open before startinggenerator.2. Set batteries are negative ground.STARTING SET1.2.3.4.5.6.Move “MASTER SWITCH” to “PRIME &RUN” position to allow fuel to prime set.Move“MASTERSWITCH”“PREHEAT” position and hold for (1)minute.NOTE: Preheat is not required when engineis hot.Move “MASTER SWITCH” to “START”position and hold until engine fires continu-ously. If engine does not start within 15seconds repeat steps 1 and 2.“MASTER SWITCH” will return to“PRIME & RUN” position when released.If running from auxiliary fuel source, move“MASTER SWITCH” to “PRIME & RUNAUX FUEL” position.After warm up. Check frequency andvoltage and adjust if necessary.Move “AC CIRCUIT BREAKER” to “ON”position.STOPPING SET1. Move“AC CIRCUIT BREAKER” to“OFF” position.2. Move “MASTER SWITCH” to “OFF”position.INSP STAMP:3. For emergency stop pull “DC CONTROLCIRCUIT BREAKER.”Change 91 - 5
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business