TM 5-6115465-34
TO 35C2-3-446-2
NAVFAC P-8-625-34
TM 068 S8B/06859D-34
50/60 Hz GOVERNOR CONTROL UNIT RESISTANCE TEST VALUES
Table 4-2.
P1
POTENTIOMETER
NOMINAL
ALLOWABLE RESISTANCE
POSITION
RESISTANCE (OHMS)
RANGE (OHMS)
CONNECTION
5100
3400 - 6800
(T-N) (T+)
1950 - 2400
M-N (M+)
2180
(M+)
R18 counterclockwise
12.180
11,000 - 13,000
F-N (F+)
6000
5000 - 7000 .
(F+)
31,000
R16 counterclwkwise
30,000 - 32,000
(F+)
5500 - 7500
R15 counterclockwise
6500
4500 - 6500
E-G (E+)
5500
R-G (R+)
100 - 140
120
F-G (F+)
500 - 750
650
J-H (J+)
Less than 0.2 ohm
T-P (T+)
1400 - 3000
2200
(T+)
R14 counterclockwise
1800 - 3400
2600
450 - 600
U-S (U+)
525
400 Hz ELECTRO-HYDRAULIC GOVERNOR CONTROL UNIT RESISTANCE TEST VALUES
Table 4-3.
ALLOWABLE RESISTANCE
POTENTIOMETER
NOMINAL
P1
RESISTANCE (OHMS)
RANGE
(OHMS)
POSITION
CONNECTION
4850
3400 - 6300
(T-N) (T+)
1200 - 1700
1400
M-N (M+)
(M+)
R18 counterclockwise
11,480
10,000 - 12,000
4160
3500 - 5500
F-N
(F+)
29,160
(F+)
R16 counterclockwise
27,000 - 319000
4000 - 5500
(F+)
R15 counterclockwise
4660
4500 - 6500
5500
E-G (E+)
R-G (R+)
120
100 - 140
550 - 750
F-G (F+)
650
J-H (J+)
Less than 0.2 ohm
1400 - 2500
T-P (T+)
1950
1500 - 2800
2150
(T+)
R14 counterclockwise
450 - 600
520
U-S (U+)
4-26 Change 5