P-9-TM-457-35 T.O. 35C2-3-442-2
TM-07464A-35 TM 5-6115 -457-34
1.
13.
Screw assembly (6)
Screw (2)
2.
14.
Screw assembly (4)
Gasket
15.
3.
Nut assembly (4)
Screw assembly (2)
4.
Screw assembly (2)
16.
Connector
17.
5.
Duplex receptacle
Cable strap
18.
6.
Nut
Terminal lug
Lock washer
19.
7.
Wire (5)
20.
8.
Circuit breaker
Insulating tubing
9.
21.
screw (2)
Cover
10.
22.
Nut (2)
Screw assembly (4)
23.
11.
Identification plate
Nut assembly (4)
24.
12.
Housing
Cover
approved cleaning solvent and dry thorough-
400 HERTZ CONVENIENCE
6-66.
ly.
RECEPTACLE ASSEMBLY.
6-70. INSPECTION.
6-67. REMOVAL. To remove the assem-
bly (located below the control cubicle), dis-
connect plug P48 from the receptacle con-
a. Inspect connectors for bent, broken
nector J48 in the rear of the assembly,
securing the assembly to the rear housing.
and surrounding pins.
6-68. DISASSEMBLY. Refer to figure
b. Check terminal lugs and soldered
6-14 and disassemble the 400 hertz con-
connections for condition and security.
venience receptacle assembly in the order
of index numbers assigned. Pay particular
c. Check circuit breakers and recep-
attention to the following:
d. Inspect sheet metal parts for dents,
a. Remove six screw assemblies (1)
and separate the cover (5) from the housing
cracks, and distortion.
(26).
6-71. REPAIR.
b. Tag and disconnect wires from con-
nector (4), circuit breaker (22), and recep-
a. Repair defective wiring in accord-
tacles (13 and 19).
6-69. CLEANING. Clean all components
b. Straighten dented or distorted sheet
with a clean lint-free cloth moistened in an
metal parts using proper tools.
6-35