P-8-627-34
T O 35C2-3-442-2
TM-07464A-35
TM 5-6115-457-34
Table 2-3. Troubleshooting (Continued)
PROBABLE CAUSE
CORRECTIVE ACTION
MALFUNCTION
DUMMY LOAD KIT (Continued)
a. Defective contactor K1,
a. Test and replace if defec-
77. Dummy load kit
Load does not change
K2, K3, or K4.
when load selector
switch is rotated.
78. Dummy load is
a. Defective contactor K1,
a. Test and replace if defec-
K2, K3, or K4.
unbalanced.
b. Test and replace if defec-
b. Defective heater
elements.
c. Test and repair if defec-
c. Defective wiring
harness.
13-26).
2-57
Change 8