CHAPTER 3 ENGINE AND GENERATOR REPAIR INSTRUCTIONS
Figure 31. Starter Assembly, Exploded View (Sheet 1 of 2)

TM-9-6115-464-34 Generator Set Diesel Engine Driven Tactical Skid Mtd 15 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Page Navigation
  34    35    36    37    38  39  40    41    42    43    44  
ARMY TM 9-6115-464-34 AIR FORCE TO 35C2-3-445-2 NAVY  NAVFAC  P-8-624-34 (16) (17) (18) (19) (20) (21) (22) (23) (24) (25) (26) Remove nut (56), flat washer (57), and insulating washer (58). Remove screws (59) to remove pole shoes (60), field coil assembly (61) and insulator (62). Remove and discard o-ring (63) and packing (64). Remove screws (65) and Iockwashers (66) to remove drive housing (67) and gasket (68). Discard gasket. Remove plug (69) and oil wick (70). Do not remove bushing (71) unless inspection reveals defects. Remove plug (72) to remove pivot pin (73). Remove retaining ring (74) and retainer (75). Rotate clutch assembly (76) counterclockwise to remove from shaft of armature (54). Remove shift lever (77), but do not remove bushings (78 and 79) or guide pin (80) from shifter housing (81 ) unless inspection reveals defects. Remove bushing (82) and o-ring (83). c. Cleaning, Inspection, and Repair. WARNING Solvent, Dry Cleaning P-D-680, Type  II is flammable and moderately toxic to skin, eyes and respiratory tract. Eye and skin protection required. Good general ventilation is normally adequate. Failure to observe this warning could result in servere personnel  injury. (1) (2) (3) (4) 3-2 WARNING Compressed air used for cleaning and drying purposes can create airborne particles that may enter the eyes. Pressure shall not exceed 30 psig and use only with adequate chip guards and chipping goggles. Failure to observe this warning could result in servere personnel injury. CAUTION Do not use dry cleaning solvent to clean electrical parts. Failure to observe this caution could result in equipment damage. Clean all metal non-electrical parts in solvent P-D-680 Type II and dry thoroughly with filtered compressed  air. CAUTION When cleaning field coils, use extreme care to avoid damaging protective insulation. Failure to observe this caution could result in equipment damage. Clean field coils with a clean, lint-free cloth lightly moistened with solvent P-D-680 Type II and dry thoroughly with filtered compressed air. Remove loose particles from armature with filtered compressed air and wipe clean with a cloth lightly moistened with an approved solvent. Clean commutator lightly with No. 00 grit sand paper. Remove all traces of dust with low pressure compressed air. Clean non-metallic washers, insulators, and seals with a clean, lint-free cloth lightly moistened with solvent  P-D-680  Type  Il.







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.