TM 9-6115-662-13&Pb.Remove power cable(12) from fender and connect as follows:(1)(2)Connect the plug end of power cable (12) to connector J2 (14) of the switch box located on unitA.Route the other end of cable (12) through power cable sock (10) and connect leads toappropriate load terminals (9) on unit B. Leads will be labeled with load terminaldesignations.2-3.5 External Fuel Source. Each generator set has provisions for obtaining fuel from an externalsource, such as a 55-gallon diesel fuel container. This enables operation for long intervals withoutfrequent refilling of the fuel tanks. To use an external fuel source:WARNINGBefore performing any maintenance that requires climbing on or undertrailer, make sure that trailer handbrakes are set and trailer is supportedto prevent rolling or tipping. Injury to personnel could result from trailersuddenly rolling or tipping.a.b.c.d.e.f.g.h.Place external fuel source away, but no more than 25 feet (7.6 meters) away, from the equipment.Remove fuel container adapter (figure 2-7) from accessory box. The fuel container adapter consistsof strainer clamp (l), adapter (2), pipe (3), and extension pipe (4).Make sure that the fuel container adapter components are clean.Figure 2-7. Fuel Container Adapter.Thread fuel pipe (3) into adapter (2). Thread extension pipe (4) into fuel pipe (3).Remove auxiliary fuel hose from generator set.Make sure that fittings on auxiliary fuel hose are clean.Thread one end of auxiliary fuel hose into fuel container adapter fitting and tighten.Connect free end of auxiliary fuel hose to generator set external fuel supply connection andtighten. Connection is located on generator set, near fuel tank filler cap.2-34