Home
Download PDF
Order CD-ROM
Order in Print
Section I. GENERAL INFORMATION - TM-9-6115-659-13P_26
Figure l-1. Features of AN/MJQ-35.
Figure 1-2 1. Features AN/MJQ-A.
Figure 1-2.2. Features of PU-797A.
Section II. EQUIPMENT DESCRIPTION
1-10. LOCATION AND DESCRIPTION OF MAJOR COMPONENTS
Figure 1-5. Location of Major Components, AN/MJQ-36.
Figure 1-6. Location of Major Components, PU-797 and PU-797A.
1-11. DIFFERENCES BETWEEN MODELS
Section III. PRINCIPLES OF OPERATION - TM-9-6115-659-13P_35
Section Ill. PRINCIPLES OF OPERATION
CHAPTER 2 OPERATING INSTRUCTIONS - TM-9-6115-659-13P_38
Section I. DESCRIPTION AND USE OF OPERATOR CONTROLS AND INDICATORS - TM-9-6115-659-13P_39
Table 2-1. Description of Switch Box Controls and Indicators - TM-9-6115-659-13P_40
Section Il. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES
2-2.4.3 Routine Inspections
2-2.6 Operation of Power Plant/Power Unit with Minor Leaks
Figure 2-2. AN/MJQ-35 Power Plant Operator PMCS Routing Diagram
Figure 2-3. AN/MJQ-36 Power Plant Operator PMCS Routing Diagram.
Figure 2-3.1. AN/MJQ-35A Power Plant Operator PMCS Routing Diagram.
Figure 2-3.2 PU-797A Power Unit Operator PMCS Routing Diagram.
Figure 2-4. PU-797 Power Unit Operator PMCS Routing Diagram.
Table 2-2. Operator Preventive Maintenance Checks and Services - TM-9-6115-659-13P_49
Operator Preventive Maintenance Checks and Services - continued - TM-9-6115-659-13P_50
Operator Preventive Maintenance Checks and Services - continued - TM-9-6115-659-13P_51
Operator Preventive Maintenance Checks and Services - continued - TM-9-6115-659-13P_52
Table 2-2. Operator Preventive Maintenance Checks and Services - TM-9-6115-659-13P_53
Operator Preventive Maintenance Checks and Services -cont - TM-9-6115-659-13P_54
Operator Preventive Maintenance Checks and Services -cont - TM-9-6115-659-13P_55
Operator Preventive Maintenance Checks and Services -cont - TM-9-6115-659-13P_56
Operator Preventive Maintenance Checks and Services -cont - TM-9-6115-659-13P_57
Operator Preventive Maintenance Checks and Services -cont - TM-9-6115-659-13P_58
Operator Preventive Maintenance Checks and Services -cont - TM-9-6115-659-13P_59
Operator Preventive Maintenance Checks and Services -cont - TM-9-6115-659-13P_60
Operator Preventive Maintenance Checks and Services -cont - TM-9-6115-659-13P_61
Operator Preventive Maintenance Checks and Services -cont - TM-9-6115-659-13P_62
Operator Preventive Maintenance Checks and Services -cont - TM-9-6115-659-13P_63
Operator Preventive Maintenance Checks and Services -cont - TM-9-6115-659-13P_64
Operator Preventive Maintenance Checks and Services -cont - TM-9-6115-659-13P_65
Operator Preventive Maintenance Checks and Services -cont - TM-9-6115-659-13P_66
Operator Preventive Maintenance Checks and Services -cont - TM-9-6115-659-13P_67
Section III. OPERATION UNDER USUAL CONDITIONS - TM-9-6115-659-13P_68
Figure 2-6. Auxiliary fuel (Typical).
2-3.3 Grounding of Generator Set.
Figure 2-7. Ground Rod and Slide Hammer.
2-3.4 Connecting Load
Figure 2-8. Power Plant and Power Unit Ground Connections
Figure 2-9. Switch Box Load Cable Connections.
2-5.3.1 Operating a Single Generator Set
2-5.3.2 Load Transfer
2-5.3.3 Stopping Generator Set.
Figure 2-12. AN/MJQ-36 Identification/Transportation Data Plate.
Figure 2-13.1. AN/MJQ-35A Shipping Data/Identification Plate.
Figure 2-13.3. AN/MJQ-35A and PU-797A Trailer Chassis Identification Plate.
24-.7 Power Plant Instruction Plate.
2-7 PREPARATION FOR MOVEMENT. - TM-9-6115-659-13P_82
Figure 2-15. Remove Ground Rod
2-7.4 Retrieve Fire Extinguisher(s)
Figure 2-16. Disconnect Auxiliary Fuel (Typical).
Section IV. OPERATION UNDER UNUSUAL CONDITIONS - TM-9-6115-659-13P_86
CHAPTER 3 OPERATOR MAINTENANCE
Section I. OPERATOR LUBRICATION - TM-9-6115-659-13P_88
Section II. TROUBLESHOOTING - TM-9-6115-659-13P_89
Figure 3-1. ON Indicator Lamp Falls to Light With Generator Set Running.
Figure 3-2. ON-LINE Indicator Lamp Fails To fight When ON/OFF Switch Is Placed In ON Position
Figure 3-3. SYNCHRONEING Indicator Lamps Fall To Light When TRANSFER Switch Is Operated
Figure 3-4. With All Indicator Lamps Working Properly, Load Will Not Transfer. - TM-9-6115-659-13P_93
Figure 3-5. Synchronizing Indicator Lamps Fail To Operate ln Unison When Transfer Switch Is Operated.
Section III. MAINTENANCE PROCEDURES - TM-9-6115-659-13P_95
CHAPTER 4 UNIT MAINTENANCE - TM-9-6115-659-13P_97
Section VII - TM-9-6115-659-13P_98
Section I. REPAIR PARTS; SPECIAL TOOLS; TEST, MEASUREMENT, AND DIAGNOSTIC EQUIPMENT (IMDE); AND SUPPORT EQUIPMENT
Section Il. SERVICE UPON RECEIPT - TM-9-6115-659-13P_100
4-5 INSTALLATION INSTRUCTIONS
4-5.2.2 Assembly of Power Plant AN/MJQ-35A
Figure 4-1. Installation of Power Cables (Sheet 1 of 2).
Figure 4-1. Installation of Power Cables (Sheet 2 of 2).
Figure 4-1.1. Installation of Power Cables on AN/MJQ-35A.
4-6 PRELIMINARY SERVICING AND ADJUSTMENT OF EQUIPMENT
Figure 4-2. PU-797 and PU-797A Ground Wire Installation.
Section III. UNIT LUBRICATION - TM-9-6115-659-13P_108
Section IV. UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-9-6115-659-13P_109
Figure 4-4. Unit PMCS Routing Diagram (Sheet I of 2).
Figure 4-4. Unit PMCS Routing Diagram (Sheet 2 of 2).
Table 4-1. Unit Preventive Maintenance Checks and Services - TM-9-6115-659-13P_112
Section V. TROUBLESHOOTING - TM-9-6115-659-13P_113
Figure 4-5. ON Indicator Lamp Serviceable But Fails 10 Light With Generator Set Running
Figure 4-6. ON-LINE Indicator Lamp Serviceable But Fails To Light When ON/OFF Switch IS Placed In ON Posilion
Figure4-7. SYNCHRONfZING lndicator Lamps Fail To Light When TRANSFER Switch ls Operated.
Figure 4-8. No Power To Load Wtih ON-LINE lndicaforLamp On.
Figure 4-9. All lndicator Lamps Working Properly But Load Will Not Transfer
Section VI. MAINTENANCE PROCEDURES
Figure 4-10. Power Cable Connections to Switch Box Contactors.
Figure 4-11. Disconnect Power Cable from Generator Set. - TM-9-6115-659-13P_121
Figure 4-12. Disconnect Power Cable From Switch Box Terminals.
INSTALLATION - TM-9-6115-659-13P_123
2. Insert terminal lug - TM-9-6115-659-13P_124
4-13 SWITCH BOX MAINTENANCE
Figure 4-13. Switch Box Repair
2. DATA PLATE REPLACEMENT
4-14 INDICATOR LIGHT ASSEMBLY MAINTENANCE
Table 4-2. Indicator Light Assernbly Test Points
4-15. SYNCHRONIZING LIGHT MAINTENANCE
TEST - TM-9-6115-659-13P_131
4-16 TOGGLE SWITCH MAINTENANCE. - TM-9-6115-659-13P_132
Figure 4-16. Toggle Switch
4-17 SWITCH BOX LOAD TERMINAL MAINTENANCE.
Figure 4-17. Switch Box Load Terminal Maintenance (Sheet 1 of 2). - TM-9-6115-659-13P_135
Figure 4-17. Switch Box Load Terminal Maintenance (Sheet 2).
4-18 LOAD TERMINAL COVER MAINTENANCE
Figure 4-18. Loud Terminal Cover.
4-19 ACCESSORY BOX MAINTENANCE. - TM-9-6115-659-13P_139
Figure 4-20. Repair Accessory Box.
4-20 FIRE EXTINGUISHER BRACKET MAINTENANCE - TM-9-6115-659-13P_141
4-21 TRAILER LIFTING RING MAINTENANCE.
4-22 DATA PLATE AND REFLECTOR MAINTENANCE
Figure 4-21.1. Identification/Transportation Data Plate and Reflector Replacement.
Figure 4-22. Shipping Data/identification Plate Replacement
4-23 AN/MJQ-35 TRAILER SPLASH GUARD, BRACKET, AND FENDER MAINTENANCE
Figure 4-23. AN/MJQ-35 Splash Guard, Bracket, Ground Stud, and Fender
INSTALLATION - TM-9-6115-659-13P_148
4-24. PU-797 AND AN/MJQ-36 TRAILER PLATFORM MAINTENANCE
4-25 PU-797 FENDER MAINTENANCE
Figure 4-25. PU-797 Fender.
INSTALLATION - TM-9-6115-659-13P_152
4-26 AN/MJQ-36 FENDER MAINTENANCE
Figure 4-26. AN/MJQ-36 Fender.
INSTALLATION - TM-9-6115-659-13P_155
4-27 1 TON TRAILER REAR LEVELING-SUPPORT JACK MAINTENANCE
Figure 4-27. Rear Leveling-Support Jack Replacement, 1 Ton Trailer.
Figure 4-28. Rear Leveling-Support Jack Repair, 1 Ton Trailer.
4-28 PU-797A AND AN/MJQ-35A GROUND STUD REPLACEMENT
Section VII. ADMINISTRATIVE STORAGE - TM-9-6115-659-13P_160
CHAPTER 5 DIRECT SUPPORT MAINTENANCE - TM-9-6115-659-13P_161
Section I. REPAIR PARTS; SPECIAL TOOLS; TEST, MEASUREMENT, AND DIAGNOSTIC EQUIPMENT (TMDE); AND SUPPORT EQUIPMENT - TM-9-6115-659-13P_162
Section II. TROUBLESHOOTING - TM-9-6115-659-13P_163
Figure 5-1. ON Indicator Lamp Assembly Tests Good, But On Indicator Lamp Fails To Light With Generator Set Running
Figure 5-2. ON-LINE Indicator Lamp Assembly And ON/OFF Switch Serviceable, But ON-LINE Indicator Lamp Fails To Light When ON/OFF Switch Is Placed IN ON Position
Figure 5-3. SYNCHRONIZINGING Indicator Lamps And Transfer Switch Serviceable, But SYNCHRONIZING Indicator Lamps Fail To Light When TRANSFER Switch Is Closed And Then Released
Figure 5-4. All Indicator Lamps Working Property, But Load Will Not Transfer.
Section III. MAINTENANCE PROCEDURES - TM-9-6115-659-13P_168
Figure 5-5. Power/Load Cable Removal. - TM-9-6115-659-13P_169
3. Remove four nuts
Figure 5-6. AN/MJQ-35 Roadside Fender Assembly Removal
Figure 5-7. Removing Generator Set Mounting Hardware (Sheet 1 of 2).
Figure 5-7. Removing Generator Set Mounting Hardware (Sheet 2 of 2).
INSTALLATION - TM-9-6115-659-13P_174
Figure 5-8. Switch Box Components.
5-7 ELECTRICAL LEADS W3-W8 MAINTENANCE
Figure 5-9. Switch Box Lead Connections.
5-8 SWITCH BOX HARNESS W9 MAINTENANCE.
Figure 5-10. Switch Box Relay Board Assembly
Table 5-1. Switch Box Harness Wire List
Figure 5-11. Disconnect Switch Box Harness W9 From Contactor.
Figure 5-13. Relay Board Assembly Removal.
INSTALLATION - TM-9-6115-659-13P_183
5-9 RELAY BOARD HARNESS W11 MAINTENANCE - TM-9-6115-659-13P_184
Figure 5-14. Relay Board Harness Assembly W11 Removal.
REMOVAL - TM-9-6115-659-13P_186
Tdble 5-3. Output Connector Harness Continuity Check
Figure 5-15. Output Connector Harness.
5-11 RELAYS K3-K6 MAINTENANCE.
Figure 5-17. Relay K3-K6 Schematic.
5-12 PERMISSIVE PARALLELING RELAY MAINTENANCE. - TM-9-6115-659-13P_191
REMOVAL - TM-9-6115-659-13P_192
5-13 CONTACTORS K1 AND K2 MAINTENANCE
Figure 5-19. Replace Contactor
Table 5-5. Contactor Operation
5-14 RESISTORS RI-R3 MAINTENANCE.
Figure 5-20. Resistors, Capacitors, and Diodes.
5-15 CAPACITORS C1-C4 MAINTENANCE.
5-16 DIODES CR1-CR4 MAINTENANCE
5-16.1 PU-797A AND AN/MJQ-35A FLOOR AND FENDER MAINTENANCE.
Figure 5-20.1. PU-797A and AN/MJQ-35A Floor Replacement.
Figure 5-20.2. PU-797A and AN/MJQ-35A Fender Replacement.
5-17 AN/MJQ-35, AN/MJQ-36, AND PU-797 TRAILER FENDER REPAIR
Figure 5-21. Replace AN/MIQ-35 Generator Mounting Rail.
5-19 AN/MJQ-35 GENERATOR MOUNTING RAIL MAINTENANCE
Figure 5-22. Replace AN/WJQ-36 Generator Mounting Rail.
5-20 PU-797 GENERATOR MOUNTING RAIL MAINTENANCE.
Figure 5-23. Replace PU-797 Generator Mounting Rail.
5-21 AN/MJQ-35 TRAILER LIFTING BRACKET MAINTENANCE
Figure 5-24. AN/MJQ-35 Trailer Lifting Bracket.
INSTALLATION - TM-9-6115-659-13P_211
2. INSTALL REAR LIFTING BRACKET
5-22 PU-797A AND AN/MJQ-35A GENERATOR MOUNTING RAIL MAINTENANCE
Figure 5-25. PU-797A and AN/MJQ-35A Generator Mounting Rail Replacement.
5-23 HIGH MOBILITY TRAILER REAR LEVELING-SUPPORT JACK MAINTENANCE.
Figure 5-26. Rear Leveling-Support Jack Replacement, High Mobility Trailer.
APPENDIX A REFERENCES - TM-9-6115-659-13P_217
A-7 MILITARY STANDARDS.
A-9 LUBRICATION ORDERS
APPENDIX B MAINTENANCE ALLOCATION CHART - TM-9-6115-659-13P_221
B-3 EXPLANATION OF COLUMNS IN THE MAC
B-4 EXPLANATION OF COLUMNS IN TOOL AND TEST EQUIPMENT REQUIREMENTS - TM-9-6115-659-13P_223
Section II. MAINTENANCE ALLOCATION CHART - TM-9-6115-659-13P_224
MAINTENANCE ALLOCATION CHART -cont
Section III. TOOL AND TEST EQUIPMENT REQUIREMENTS - TM-9-6115-659-13P_226
Section IV. REMARKS - TM-9-6115-659-13P_227
APPENDIX C COMPONENTS OF END ITEM (COEI) AND BASIC ISSUE ITEMS (Bll) USTS
SECTION II. COMPONENTS OF END ITEM - TM-9-6115-659-13P_230
SECTION III. BASIC ISSUE ITEMS
APPENDIX D ADDITIONAL AUTHORIZATION LIST - TM-9-6115-659-13P_233
APPENDIX E EXPENDABLE AND DURABLE ITEMS LIST - TM-9-6115-659-13P_235
SECTION II.EXPENDABLE AND DURABLE ITEMS LIST
APPENDIX F UNIT AND DIRECT SUPPORT MAINTENANCE REPAIR PARTS AND SPECIAL TOOLS LIST - TM-9-6115-659-13P_237
F-3.2 SMR CODE - TM-9-6115-659-13P_238
F-3.2.2 Maintenance Code - TM-9-6115-659-13P_239
F-3.2.3 Recoverability Code. - TM-9-6115-659-13P_240
F-3.5 DESCRIPTION AND USABLE ON CODE
F-5 SPECIAL INFORMATION.
F-6 HOW to LOCATE REPAIR PARTS - TM-9-6115-659-13P_243
Figure F- 1. Generator Set, Installation.
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_247
Figure F-2. Generator Set, Power Unit.
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_249
Figure F-3. Power Cables.
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_251
Figure F-4. Cable Assembly
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_253
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_254
Figure F-5. Switch Box Installation
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_257
Figure F-6. Relay Board Harness Assembly (Sheet 1 of 2) - TM-9-6115-659-13P_259
F-6. Wire Parts List (Sheet 2 of 2)
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_261
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_262
Figure F-7. Permissive Paralleling Relay
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_265
Figure F-8. Indicator Lights
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_267
Figure F-9. Light Assembly
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_269
Figure F-10. Switches
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_271
Figure F-11. Load Terminal Cover - TM-9-6115-659-13P_272
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_273
Figure F-12. Load Terminal
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_275
Figure F-13. Electrical Leads - TM-9-6115-659-13P_276
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_277
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_278
Figure F-14. Output Connector Harness Assembly
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_281
Figure F-15. Switch Box Harness Assembly (Sheef 1 of 2)
Figure F-15. Switch Box Harness Assembly (Sheet 2 of 2)
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_285
Figure F-16. Contactor
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_287
Figure F-17. Resistor R3 - TM-9-6115-659-13P_288
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_289
Figure F-18. Switch Box Assembly
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_291
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_292
Figure F-20. Accessory Box
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_294
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_295
Figure F-21. Power Plant Fire Extinguisher, Oil Drain and Ground Wire. (Sheet 1 of 2)
Figure F-21. Power Plant Fire Extinguisher, Oil Drain and Ground Wire. (Sheet 2 of 2)
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_298
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_299
Figure F-22. Power Unit Fire Extinguisher, Oil Drain and Ground Wire (Sheet 1 of 2).
Figure F-22. Power Unit Fire Extinguisher, Oil Drain and Ground Wire (Sheet 2 of 2).
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_302
Figure F-23. Platforms
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_304
Figure F-24. Power Plant/Power Unit trailer Assembly (Sheet 1 of 2).
Figure F-24. Power Plant/Power Unit Trailer Assembly (Sheet 2 of 2) - TM-9-6115-659-13P_306
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_307
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_308
Figure F-25. Splash Guard
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_310
Figure F-26. Fenders, Rails, Lifting Rings and Brackets, One Ton Trailer, AN/MJQ-35
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_312
Figure F-27. 1 1/2 Ton Trailer, AN MJQ-36 Fender
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_314
Figure F-28. Fenders, One Ton Trailer, PU-797
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_316
Figure F-29. High Mobility Trailer, Mounting Rails and Fenders, (AN/MJQ-35A and PU-797A). (Sheet 1 of 2)
Figure F-29. High Mobility Trailer, Mounting Rails and Fenders, (AN/MJQ-35A and PU-797A). (Sheet 2. of 2)
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_319
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_320
Figure F-30. Jack Leveling-Support Assembly.
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_322
Figure F-31. Power Plant/Power Unit Trailer Chassis Assembly.
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_324
DESCRIPTION AND USABLE ON CODES - TM-9-6115-659-13P_325
SECTION IV CROSS- REFERENCE-INDEXES - TM-9-6115-659-13P_328
NATIONAL STOCK NUMBER INDEX - TM-9-6115-659-13P_329
STOCK NUMBER - TM-9-6115-659-13P_330
CROSS-REFERENCE INDEXES - TM-9-6115-659-13P_331
PART NUMBER INDEX - TM-9-6115-659-13P_332
PART NUMBER - TM-9-6115-659-13P_333
PART NUMBER - TM-9-6115-659-13P_334
PART NUMBER - TM-9-6115-659-13P_335
PART NUMBER - TM-9-6115-659-13P_336
PART NUMBER - TM-9-6115-659-13P_337
PART NUMBER - TM-9-6115-659-13P_338
PART NUMBER - TM-9-6115-659-13P_339
FIGURE AND ITEM NUMBER INDEX - TM-9-6115-659-13P_340
FIGURE AND ITEM NUMBER INDEX - TM-9-6115-659-13P_341
FIGURE AND ITEM NUMBER INDEX - TM-9-6115-659-13P_342
FIGURE AND ITEM NUMBER INDEX - TM-9-6115-659-13P_343
FIGURE AND ITEM NUMBER INDEX - TM-9-6115-659-13P_344
FIGURE AND ITEM NUMBER INDEX - TM-9-6115-659-13P_345
FIGURE AND ITEM NUMBER INDEX - TM-9-6115-659-13P_346
FIGURE AND ITEM NUMBER INDEX - TM-9-6115-659-13P_347
FIGURE AND ITEM NUMBER INDEX - TM-9-6115-659-13P_348
APPENDIX G ILLUSTRATED LIST OF MANUFACTURED lTEMS
DIMENSIONS AND PARTS LIST
Figure G-2. Relay Board Harness Assembly W11 (sheet 1 of 2)
Figure G-2. Relay Board Harness Assembly W11 (Sheet 2). - TM-9-6115-659-13P_352
Figure G-3. Swich Box Harness Assembly W9 (sheet 1 of 4)
Figure G-3. Swich Box Harness Assembly W9 (sheet 2 of 4)
Figure G-3. Swich Box Harness Assembly W9 (sheet 3 of 4)
Figure G-3. Swich Box Harness Assembly W9 (sheet 4 of 4)
Figure G-4. Output Connector Harness Assembly W10 (Sheet 1 of 2).
Figure G-4. Output Connector Harness Assembly W10 (Sheet 2). - TM-9-6115-659-13P_358
Figure G-5. Cable Assembly W1 and W2 (Sheet 1 of 3).
Figure G-5. Cable Assembly W1 and W2 (Sheet 2)
Figure G-5. Cable Assembly WI and W2 (Sheet 3).
Figure G-6. Deck Covering
Figure G-7. Switch Box Gasket.
APPENDIX H. OTRQUE LIMITS
APPENDIX I MANDATORY REPLACEMENT PARTS - TM-9-6115-659-13P_367
GLOSSARY - TM-9-6115-659-13P_368
Section II. DEFINITION OF UNUSUAL TERMS - TM-9-6115-659-13P_369
Figure FO-1. Power Plant Wiring Diagram.
FO-2. POWER PLANT SCHEMATIC
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business