ARMY TM 9-6115-604-12NAVY NAVFAC P-8-633-12Table 1-1. System Capacities and Detailed Data on Components (Continued)9. CONTROLS, INSTRUMENTS, AND SWITCHGEAR (CONTINUED)Current Boost Transformers CT2 and CT3Drawing Number:80-7547Input Power:Terminals 1 to 2:1200 to 3000 ATerminals 1 to 3:3000 to 7000 AOutput Power:180 V dc, 5 ABurden:10 V aTerminals0.164-32 screw typeOperating Temperature-25 to +125°F (-31 to 51°C)Storage Temperature-65 to + 155°F (-53 to 68°C)Humidity Conditions.To 100%Manufacturer.Basler Electric CompanyPart Number.BE15486-001FSCM97520Voltage Regulator Transformer T102Drawing Number80-7552Pnmary Voltage:2400/4160 V acSecondary Voltage120/240 V acDielectric Test Voltage:Primary12,000 V acSecondary2500 V acOperating Frequency Range50/60 hzFuses3 in primaryPrimary Rating:1000 V aOperating Temperature-25 to +125°F (-31 to 51°C)Storage Temperature-65 to +155°F (-53 to 68°C)Humidity ConditionsTo 100%Manufacturer::Basler Electric CompanyPart Number:BE13616-001FSCM97520Generator and Bus Instrument TransformersT104 and T106 through T11 0Drawing Number80-7407Specification'ANSI C57.13Voltage Class5000 vVoltage Ratio.2400/120 V acAccuracy90 to 110%, volts 0.6%, 50/60 HzContinuous Rating (Thermal)450 V amperesPrimary and Secondary Terminals190-32 into 375 deep brass inserts primary slave terminals provided for primary fuses coreand windings encased in thermoplastic and filled under vacuum with resinOperating Temperature.-25 to +125°F (-31 to 51°C)Storage Temperature:-65 to +155°F (-53 to 68°C)Humidity Conditions.To 100%Manufacturer.Instrument Transformer CompanyPart Number:PT3-45242FB20FSCM:591381-46